Installation, Safety precautions read, Select suitable location – Lincoln Electric IM10007 POWER WAVE S350 User Manual

Page 10: Warning lifting, Stacking, Tilting, Input and ground connections, Machine grounding, High frequency protection, Warning

Advertising
background image

A-3

INSTALLATION

POWER WAVE

®

S350

A-3

SAFETY PRECAUTIONS Read

this

entire installation section before you start installa-

tion.

ELECTRIC SHOCK can kill.

• Only qualified personnel should

perform this installation.

• Turn the input power OFF at the

disconnect switch or fuse box before working on
this equipment. Turn off the input power to any
other equipment connected to the welding system
at the disconnect switch or fuse box before work-
ing on the equipment.
• Do not touch electrically hot parts.
• Always connect the POWER WAVE

®

S350

grounding lug to a proper safety (Earth) ground.

-------------------------------------------------------------

SELECT SUITABLE LOCATION

The POWER WAVE

®

S350 will operate in harsh envi-

ronments. Even so, it is important that simple preven-
tative measures are followed in order to assure long
life and reliable operation.

• The machine must be located where there is free

circulation of clean air such that air movement in
the back, out the sides and bottom will not be
restricted.

• Dirt and dust that can be drawn into the machine

should be kept to a minimum. The use of air filters
on the air intake is not recommended because nor-
mal air flow may be restricted. Failure to observe
these precautions can result in excessive operating
temperatures and nuisance shutdown.

• Keep machine dry. Shelter from rain and snow. Do

not place on wet ground or in puddles.

• Do not mount the POWER WAVE

®

S350 over com-

bustible surfaces. Where there is a combustible
surface directly under stationary or fixed electrical
equipment, that surface shall be covered with a
steel plate at least .060” (1.6mm) thick, which shall
extend not less than 5.90” (150mm) beyond the
equipment on all sides.

WARNING

LIFTING

Both handles should be used when lifting POWER WAVE

®

S350. When using a crane or overhead device a lifting strap
should be connected to both handles. Do not attempt to lift the
POWER WAVE

®

S350 with accessories attached to it.

STACKING

The POWER WAVE

®

S350 cannot be stacked.

TILTING

Place the machine directly on a secure, level surface or on a
recommended undercarriage. The machine may topple over if
this procedure is not followed.

INPUT AND GROUND CONNECTIONS

Only a qualified electrician should connect the POWER WAVE

®

S350. Installation should be made in accordance with the
appropriate National Electrical Code, all local codes and the
information in this manual.

MACHINE GROUNDING

The frame of the welder must be grounded. A ground terminal
marked with a ground symbol is located next to the input
power connection block.

See your local and national electrical codes for proper ground-
ing methods.

HIGH FREQUENCY PROTECTION

The EMC classification of the POWER WAVE

®

S350 is

Industrial, Scientific and Medical (ISM) group 2, class A. The
POWER WAVE

®

S350 is for industrial use only. (See print

L10093 for further details).

Locate the POWER WAVE

®

S350 away from radio controlled

machinery. The normal operation of the POWER WAVE

®

S350

may adversely affect the operation of RF controlled equipment,
which may result in bodily injury or damage to the equipment.

• Lift only with equipment of ade-

quate lifting capacity.

• Be sure machine is stable when

lifting.

• Do not operate machine while

suspended when lifting.

FALLING

EQUIPMENT can

cause injury.

-------------------------------------------------------------

WARNING

Advertising