CAUTION

PROBLEMS

(SYMPTOMS)

POSSIBLE

CAUSE

RECOMMENDED

COURSE OF ACTION

The welding arc is “cold.” The weld-
ing arc is not stable or is not satis-
factory. the engine runs normally.
The auxiliary power is normal.

1. Make sure the MODE selector

switch is in the correct position for
the process being used. (For exam-
ple, CV-WIRE, PIPE, CC-STICK.)

2. Make sure the electrode (wire, gas,

voltage, current etc.) is correct for
the process being used.

3. Check for loose or faulty connec-

tions at the weld output terminals
and welding cable connections.

4. The welding cables may be too long

or coiled, causing an excessive
voltage drop.

If all recommended possible areas of
misadjustment have been checked
and the problem persists, Contact
your local Lincoln Authorized
Field Service Facility.

Advertising