Troubleshooting, Caution – Lincoln Electric IM10124 RED-D-ARC FX450 User Manual

Page 28

Advertising
background image

E-4

TROUBLESHOOTING

E-4

FX450 (RED-D-ARC)

Observe all Safety Guidelines detailed throughout this manual

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CAUTION

Error

Code#

713

714

715

719

Description

Input Power Misconnect.
Supply Voltage is too high.

Input Power Misconnect.
Supply Voltage is too low.

Under Voltage Lockout.

Switch PCB Error.

Occurs upon power up when the supply
voltage to the switch pcb exceeded accept-
able levels.

Occurs upon power up when the supply
voltage to the switch pcb is below accept-
able levels.

The supply voltage to the switch pcb is
below acceptable levels

Verify the primary reconnect
is properly configured for the
input voltage.

Machine needs to be turned
off and back on to reset.

Verify the primary reconnect
is properly configured for the
input voltage.

Machine needs to be turned
off and back on to reset.

Machine needs to be turned
off and back on to reset.

Machine needs to be turned
off and back on to reset.

Error Codes for the FX450

Corrective Action

Possible Cause

If any of these conditions persist contact an authorized Field Service Shop.