Torch coolant specifications – Lincoln Electric 718118 Spirit II 400 User Manual

Page 17

Advertising
background image

Spirit II User’s Manual

Section 2: Specifications

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

2-5

Torch Coolant Specifications

Note: Refer to the supplier’s most current Material Safety Data Sheet for

information regarding safety, handling, and storage of torch coolant.

The Spirit system is shipped without torch coolant in the reservoir.

Coolant

must be added before applying power to the system. Only use Kaliburn

approved torch coolant solution for optimal system performance as commercially

available antifreeze contains corrosion inhibitors that will damage the cooling

system. The standard coolant solution consists of 25% industrial grade

propylene glycol and provides freezing protection down to -13º C (9º F). The

standard solution can be ordered in one-gallon containers, PN 500695. For

operating temperatures below -13º C, a 50% solution of industrial grade

propylene glycol can be ordered in one-gallon containers, PN 500895, providing

protection down to -36º C (-33º F).

Failure to use the proper propylene glycol solution may result in cooling

system and/or torch damage.

The torch coolant should be flushed out of the Spirit system every six months

and replaced with new coolant. The coolant filter / deionization cartridge should

also be changed at the same time. See Section 6 for details.

Advertising