Checking system status – Lincoln Electric 718117 Spirit II 400 User Manual

Page 51

Advertising
background image

Spirit II User’s Manual

Section 4: Operation with Automatic Gas Console

This information is subject to the controls of the Export Administration Regulations [EAR]. This information shall not be provided to

non-U.S. persons or transferred by any means to any location outside the United States contrary to the requirements of the EAR.

4-5

Checking System Status

To view the system status indicators, press the Status navigation button.

Each indicator will be either Green or Red.

DC Power Indicator

Green when the main contactor has

been energized and D.C. current is

flowing through the torch. Red when no

D.C. current is flowing.

3 Phase Power Indicator

Green when 3 phase power is

satisfactory. Red when there is a

problem with main 3 phase power.

Gas Console Indicator

Green when the automatic gas console

is operational. Red when there is a

problem with the gas system. Check

the message screen for errors.

ISC Door Indicator

Green when the impulse start console

door is closed. Red when the impulse

start console door is open.

Coolant Temperature Indicator

Green when the torch coolant

temperature is satisfactory. Red when

the coolant temperature is too hot. If

this indicator turns Red, leave the

system on until it turns Green again.

Coolant Level Indicator

Green when the coolant level inside the

reservoir is satisfactory. Red when

coolant must be added.

Coolant Flow Indicator

Green when the coolant flow through

the system is satisfactory. Red when

the coolant flow is restricted.

ISC Door