C-400, Motion commands, Parameter setup – Pacific Laser Equipment C-400 User Manual

Page 20: Reporting

Advertising
background image

Motor controller 4ch

User manual

C-400

November 19, 2002

Release: 1.30

2002 by

Pacific Laser Equipment

PLEquipment, 3941 S. Bristol St. Unit D-122, Santa Ana, CA. 92704,

(

509-355-5155, Fax: 509-355-5155, Email: [email protected]

Page 20 of 21

MOTION COMMANDS

AB Abort motion

Stops the motor

FE Find edge

Move to reference point

GH Go home

Moves to the origin

MA Move absolute

Moves to absolute position

MF Motor off

No position control

MN Motor on

Set motor in position control mode

MR Move relative

Move relative to current position

ST Stop

Stops the motor

PARAMETER SETUP

BR Baud rate

Set baud rate

DH Define home

Define zero position

EF Echo off

Set echo off

EN Echo on

Set echo on

IF I-term oN

Enables Integral Term

IN I-term ofF

Disables Integral Term

LS Limit set

Set count number to step back

RT Reset

Resets the controller

SA Set acceleration

Set the acceleration rate

SD Set deceleration

Set the deceleration rate

SE Set dynamic gain

Sets the dynamic gain

SG Set gain

Sets the static gain

SO Set output

Sets output voltage

SP Set point

Sets the deceleration point

SQ Set torque

Sets the maximum output voltage

SV Set velocity

Sets the motor speed

REPORTING

CS Check sum

Reports the EPROM checksum

TD Tell deceleration

Reports programmed SD values

TE Tell following error

Reports the dynamic error

TG Tell gain

Reports programmed SG values

TI Tell iteration

Reports iteration count

TL Tell acceleration

Reports programmed SA values

TM Tell macros

Reports stored macros

TN Tell dynamic gain

Reports programmed SE values

TO Tell output

Reports output voltage command value

TP Tell position

Reports actual position

TR Tell deceleration pt.

Reports programmed SP values

TT Tell target

Reports target position

TV Tell velocity

Reports actual velocity

TY Tell commanded velocity Reports programmed SV values

Advertising