INFREQUENT SERVICE

If the unit is used infrequently, difficult starting may result.

To eliminate hard starting, run the generator at least 30 minutes
every month. Also, if the unit will not be used for some time, it
is a good idea to drain the fuel from the carburetor and gas
tank.

LONG TERM STORAGE

When the generator set is not being operated or is being

stored more than one month, follow these instructions:

1.

Replenish engine oil to upper level.

2.

Drain gasoline from fuel tank, fuel line and carburetor.

3.

Pour about one teaspoon of engine oil through the spark
plug hole, pull the recoil starter several times and replace
the plug. Then pull the starter until you feel the piston is on
its compression stroke and leave it in that position. This
closes both the intake and exhaust valves to prevent the
inside of the cylinder from rusting.

4.

Cover the unit and store in a clean, dry place that is well
ventilated away from open flame or sparks.

NOTE: The use of a fuel additive, such as Coleman

Powermate Generator Fuel Additive

®

, or an equivalent, will

minimize the formulation of fuel gum deposits during
storage. Such an additive may be added to the gasoline in
the fuel tank of the engine, or to the gasoline in a storage
container.

WARNING: To avoid possible personal injury

or equipment damage, a registered electrician or
an authorized service representative should
perform installation and all service. Under no
circumstances should an unqualified person
attempt to wire into an utility circuit.

To avoid backfeeding into utility systems, isolation of the

residence electrical system is required.

Before temporary connection of the generator to the

residence electrical system, turn off the main switch.

If your generator is to be used as a stand-by power source

in case of utility power failure, it should be installed by a
registered electrician and in compliance with all applicable local
electrical codes.

Proper use requires that a double throw transfer switch be

installed by a licensed qualified electrician so that the building's
electrical circuits may be safely switched between utility power
and the generator's output, thereby preventing backfeed into
the power utility's electrical system.

WARNING: To avoid backfeeding into utility

systems, isolation of the residence electrical
system is required. Before temporary connection
of a generator to the residence electrical system
turn off the main switch. Before making permanent
connections a double throw transfer switch must
be installed. To avoid electrocution or property
damage, only a trained electrician should connect
generator to residence electrical system.
California law requires isolation of the residence
electrical system before connecting a generator to
residence electrical systems.

10

English

INSTALLATION

SERVICE AND STORAGE

PROBLEM

POSSIBLE CAUSE

SOLUTION

Unit will not idle

Control panel switch not on

Turn to idle on position

Load plugged into receptacle

Unplug load

Poor connection or faulty cord

Check & repair

Defective I.C. module;

Replace

Defective electro-magnet;
Defective stator

Call Product Services, 1-800-445-1805

Unit idles even with load plugged in

Load not heavy enough

Turn idle switch to off position

Increase load

Defective I.C. module

Replace

Call Product Services, 1-800-445-1805

Unit tries to idle but won’t stay latched Electro-magnet or solenoid position

Reset magnet or solenoid position for

incorrect

2700 RPM idle speed

Consult dealer

Flapper bracket loose or bent

Tighten or straighten

Replace flapper. Readjust to 2700 RPM

Engine not running smoothly

Adjust carburetor

Call Product Services, 1-800-445-1805

IDLE CONTROL TROUBLE SHOOTING