Troubleshooting chart – Powermate VPP1080318 User Manual

Page 21

Advertising
background image

200-2757

21

Note: Troubleshooting problems may have similar causes and solutions.

TROUBLESHOOTING CHART

PROBLEM

POSSIBLE CAUSE

SOLUTION

Low pressure or not
enough air
or
Compressor does not
stop

Tank drain valve is open

Close drain valve

Fittings Leak

Check fittings with soapy water. Tighten or reseal leaking fittings.
DO NOT OVERTIGHTEN.

Restricted air intake

Clean or replace air filter element.

Prolonged excessive use of air

Decrease amount of air used.

Compressor not large enough

Check air requirement of accessory. If it is higher than CFM and
pressure supplied by compressor, you need a larger compressor.
Most accessories are rated at 25% of actual CFM while running
continuously.

Hole in air hose

Check and replace if necessary.

Tank leaks

Immediately replace tank. DO NOT attempt to
repair.

Blown seals

Replace compressor assembly.

Valve leaks

Replace compressor assembly.

Leaking or worn piston

Replace compressor assembly.

Air leaks from regulator,
or regulator does not
regulate pressure

Dirty or damaged regulator
internal parts.

Replace regulator or internal parts.

Regulated pressure gauge
reading drops when air
accessory is being used

This is normal

If pressure drops too low, adjust regulator while accessory is used.

Compressor not large enough

Check air requirement of accessory. If it is higher than CFM and
pressure supplied by compressor, you need a larger compressor.
Most accessories are rated at 25% of actual CFM while running
continuously.

Pressure relief valve
opens

Tank pressure exceeded normal
operating pressure

Replace pressure switch

Pressure switch stuck

Replace pressure switch

Motor will not run

Tank pressure exceeds preset
pressure switch limit

Motor will start automatically when tank pressure drops below
kick-in pressure of pressure tank.

Motor overload protection has
tripped

To reset the motor overload, toggle the pressure switch to the
“OFF’ position and unplug the unit from the power outlet. Allow a
minimum of 10 minutes for motor overload cut-out to cool and
reset. Unit can then be plugged in and restarted.

Fuse blown or circuit breaker
tripped

• Replace blown fuse or resed circuit breaker. Do not use fuse or

circuit breaker with higher rating than specified for your branch
circuit.

• Check for proper fuse; “Fusetron” type T is acceptable.

• Check for low voltage and proper extension cord size.

• Disconnect other applications from circuit. Operate compressor

on a dedicated circuit.

Check valve stuck open

Remove and clean or replace.

Pressure bleeder valve on
pressure switch has not
unloaded head pressure

Bleed line by moving pressure switch lever to OFF Position before
restarting. If bleeder valve does not open, replace bleeder valve.

Wrong wire gauge in cord or
excessive extension cord length

Check for proper gauge and extension cord length.

Loose electrical connections

Contact authorized service center.

Possible defective capacitor

Contact authorized service center.

Paint spray on internal motor
parts

Have checked at service center. Do not operate compressor in the
paint spray area

Possible defective motor

Have checked at service center.