5.3 LUBRICATION

The pressure washer is designed with a permanent lubrication
system. Conventional oil check and oil changes are not
necessary.
NOTE: IN CASE OF OIL LEAKAGE, CONTACT THE
CUSTOMER SERVICE DEPARTMENT CONCERNING
REPAIR. A SMALL AMOUNT OF LEAKAGE IS NORMAL.

5.4 WATER SCREEN

The pressure washer is equipped with a water inlet screen to
protect the pump.

CAUTION: if the screen is not kept clean, the flow of
water to the pressure washer will be restricted and
the pump may be damaged.

To clean inner conical water screen, remove quick
connect and remove the plastic screen from the pump
inlet.

Backflush screen to clean.

Replace screen and quick connect immediately to
prevent any foreign matter from entering the pump.

CAUTION: do not damage the screen while
removing or cleaning. Any foreign particles entering
the pump may damage the pump.

5.5 COOLING SYSTEM

The air vents, located in and around the pressure washer,
must be kept clean and free of any obstructions to ensure
proper air cooling of the motor during operation.

WARNING: prevent water from penetrating the
vents of the pressure washer to minimize the risk of
damage to the machine and to reduce the risk of
shock to the operator.

In a double-insulated product, two systems of
insulation are provided instead of the grounding.
No grounding means is provided on a double-
insulated product, nor should a means for
grounding be added to the pressure washer.
Servicing a double-insulated product requires

extreme care and knowledge of the system, and should be
done only by qualified service personnel. Replacement parts
for a double-insulated product must be identical to the parts
they replace. A double-insulated product is marked with the

words "DOUBLE-INSULATION" or "DOUBLE-INSULATED".
The following symbol may also be marked on the product.

C

AUTION: always store your pressure washer in a

location where the temperature will not fall below 40°F.
The pump in this machine is susceptible to permanent
damage if frozen. FREEZE DAMAGE IS NOT
COVERED BY THE WARRANTY.

In a continued commitment to improve quality, the
Manufacturer reserves the right to make component changes
or design changes when necessary.

5.0

MAINTENANCE

Fig. 6

6.0

SERVICING A DOUBLE-
INSULATED APPLIANCE

7.0

MOVING AND STORAGE
INSTRUCTIONS

8.0

TECHNICAL DATA

Pump pressure

1500 PSI Max

*Operation pressure

Electrical requirement

120v, 15 amps, 60 Hz

Electrical cord

23 ft.

High pressure hose

19 ft.

Flow rate

1.5 GPM

Minimum amperage
source

15 amp

Pressure of inlet water

20 to 100 psi

Inlet water

cold tap water

Soap consumption rate

10% Max

*Water flow and maximum pressure ratings determined in
accordance with PWMA. Standard PW101.