- INSTRUCTIONS -

The RY-24L Door Release Relay Module is an interface between the door release contact on the Aiphone monitor and the
actual release mechanism. The contact closure directly out of the monitor is rated at 12V AC with a low current capacity. If
your strike or maglock requires more voltage or current, the RY-24L is required. It provides either a Normally Open contact
for an electric strike, or a Normally Closed contact for a magnetic lock. The contact rating supports a majority of door
release hardware available on the market. The RY-24L relay is recommended with all AX, KC, KB, and JA video systems
when using the door release feature. This will protect the built-in contact from possible surge damage.
(Note: For more than one door release on the KB system, use the RY-3DL.)

RY-24L

Form C Door Release Relay for AX, KB, KC, and JA Color Video Systems

WIRING DIAGRAMS:

Page 1

INSTALLATION:

1. Install in a suitable location, either near the power source for the door release mechanism, or behind the monitor.
2. Secure wire connections with proper termination, such as wire nuts or crimp connectors.
3. Trim the wires to the desired length.
4. Trim the unused contact wire so the bare strands are not exposed.

RED: L/ORG
BLK: (-) Neg.
BRN: Common
ORG: N/O
YEL: N/C

RY-24L COLOR CODE:
Input of Relay:
Red:

L/ORG, Postive trigger

Black:

(-) NEGATIVE

Output of Relay:
Brown:

COMMON

Orange:

N/O Contact

Yellow:

N/C Contact

(See contact rating specs on
back page)

Connect RED and

YELLOW wire on

JA--2MCD/-2MECD

directly to +

A1

A2

JA-2MECD

JA-2MCD

B1

B2

A1

A2

Purp

Blu

Grn

Yel

Org

Red

Brn

L1 (Brn)
L1 (Red)
L2 (Org)
L2 (Yel)

#2

#1

PS-2420UL

+

-

Door 1

JA-DAC

A1

A2

C1

C2

C1

C2

D

O

O

R

1

S

U

B

D

O

O

R

2

A

D

A

P

T

E

R

1

A

D

A

P

T

E

R

2

Blk

Brn

Org

Yel

RY-24L

Red

LOCK

POWER

Door

Release

#1

Brn

Org

Yel

RY-24L

Door

Release

#2

Blk

Red

MAGNETIC LOCK

WIRING METHOD:

(Normally Closed contact)

+

-

LOCK

POWER

ELECTRIC STRIKE

WIRING METHOD:

(Normally Open contact)

Door 2

JA-DAC

A1

A2

COM
N/O
N/C

NOTE: The door release contacts are rated at 24V AC, 500mA. The RY-24L should be used in any application where the
strike or maglock has a higher voltage or draws more current. Otherwise, internal damage to the JA monitor could result.