AMX Mio Modero FG039.11 User Manual

Page 2

Advertising
background image

For full warranty information, refer to the AMX Instruction Manual(s) associated with your Product(s).

037-004-2985 8/06

©2006 AMX. All rights reserved. AMX and the AMX logo are registered trademarks of AMX.

AMX reserves the right to alter specifications without notice at any time.

3000 RESEARCH DRIVE, RICHARDSON, TX 75082 • 800.222.0193 • fax 469.624.7153 • technical support 800.932.6993 • www.amx.com

93-2408-20

REV: A

Mounting the Magnetic Post Housing on a Mio Modero DMS

If the Mio Modero does not already have the magnetic post housing attached,
follow these steps. The Mio Modero DMS will not stay in the conduit box
without the magnetic post housing. Only the new conduit box can be used with
the magnetic posts.
To avoid any damage to the electronic component, installation must be
performed in an ESD safe environment.
1.

If in the wall, remove the Mio Modero DMS from the conduit box. Place a
flathead screwdriver between the tab of the conduit box and the notch of
the Mio Modero DMS and pop the two apart. Pull the bottom of the unit
out (pivoting on the top clip) until it seems to bind against the shielding;
while keeping the unit at this angle, pull the top of the unit away from the
top clip.

2.

Place the Mio Modero DMS unit face down on a flat surface.

3.

Unscrew the 4 points illustrated in FIG. 3.

4.

Screw 4 standoffs provided with the conduit box kit into the holes from the
previous step.

5.

Place the hex post over the hole illustrated in FIG. 4 and fasten it down
with the screw on the bottom side of the board.

6.

Place and fasten the magnetic housing onto the standoffs as illustrated in
FIG. 5. Note the orientation of the cutout on the magnetic housing in
relation to the Mio Modero DMS board, it should not be mounted in any
other fashion. Use either the 4 screws removed in step #3 or the 4
screws provided with the kit (for those that already lost the other 4
screws).

7.

Insert the provided cardboard paint shield into the conduit box if the Mio
Modero DMS will not be installed at this time.

FIG. 3 Rear View of Mio Modero DMS

FIG. 4 4 Standoffs and Hex Post locations

4 screws

Magnetic Post Housing

4

standoffs

Hex Post

and

Screw

FIG. 5 Rear and side view of magnetic housing

Screw points for
magnetic mounting.

(Side view)

Advertising