Hydraulic system requirements, Working pressure, psi line pull, lbs first layer, Flow, gpm – Ramsey Winch H-800 W/AIR SHIFTER (TALBERT) User Manual

Page 8: Lin e speed, fpm first layer

Advertising
background image

HYDRAULIC SYSTEM REQUIREMENTS

Refer to the performance charts, below, to properly match your hydraulic system to H-800 Dow-Lok® winch per-
formance. The charts consist of :

(1) Line pull (lb.) first layer vs. working pressure (PSI). STATIC (solid line) refers to hoisting a suspended load from

rest; DYNAMIC (dotted line) refers to maintaining the motion of a moving load.

(2) Line speed, first layer (FPM) vs. Flow, gallons per minute (GPM).

Performance based on a motor displacement of 14.9 cubic inches with 30 GPM maximum flow rate. See page 17
for motor port size.

H-800 Series Performance
20,000 lb. Duty Rating 40:1 Gear Ratio

TYPICAL HYDRAULIC LAYOUT

WORKING PRESSURE, PSI

LINE PULL, LBS

FIRST LAYER

6,000

0

8,000

10000

12,000

14,000

16,000

STATI

C

DYNAM

IC

2000

1000

3000

FLOW, GPM

10

LIN

E

SPEED, FPM

FIRST LAYER

0

0

10

5

15

20

20

30

18,000

20,000

8

Advertising