F. STANDARD PROGRAM- DATA INSTRUMENTS INTERFACE (J52)TB1-7)
With the jumper in place, the standard program is active. Remove jumper, recycle
power and the Data Instruments program is active. Only the manual mode will work
with the keys at this time.

G. KEYPAD AND DISPLAY INTERFACE (RS232 PORT)
The keypad/display is the interface between the operator and the resident program.
The Pacific Scientific drive is purchased with a great many capabilities, none of which
can be used unless a program is written to utilize these capabilities. Rapid-Air put a
great deal of time making a program that is user friendly and yet gets the job done
efficiently. We took all the questions and constructive criticism and came up with a
program that would cover all the applications, yet be easy to interface and program by
a customer.

If an operator reads the programming procedure in this manual and then reads the
screen parameters listed as they are displayed and acts on them by inputting data as
needed, the servo can be up and running in a very short time.
1. Select a job number.
2. Input or review parameter for that job number.
3. Thread up material in manual mode.
4. If properly interfaced, go into automatic mode.