Troubleshooting guide – Rapid-Air STRAIGHTENER / RAPID-ROLL: SA3 - SD with compact control User Manual

Page 14

Advertising
background image



MAIN SWITCH ON BUT NOT LIT

1. CB tripped.

a. Reset CB.

2. Unit not plugged into main power.

a. Plug into main power source.

3. no power in incoming line.

a. Check outlet.

b. Check power cord.

4. Loose wiring.

a. Check terminals and connections.

MOTOR CREEPS IN STOP POSITION

1. R1 & R3 pot on 69100034 board not

correctly adjusted.

a. Readjust pots so rollers stop.

Call factory.

UNIT TURNS BUT WON’T JOG

1. Selector switch not in jog position.

a. Select jog.

2. Jog pot on 69100076 board not

adjusted correctly.

a. Adjust pot. Call factory

3. Maximum speed pot on Ramm

board set too low.

a. Adjust pot.

UNIT ON BUT MOTOR WON’T RUN.

(ARMATURE VOLTAGE PRESENT –

ON RAMM BOARD)

1. Check motor wiring and fuse.

a. Replace motor cord and correct

motor wiring. Call factory.

2. Check motor.

a. Worn brushes or motor

defective. Call factory.

UNIT ON BUT MOTOR WON’T RUN.

(NO ARMATURE VOLTAGE ON

RAMM BOARD)

1. Selector switch not in run

position.

a. Turn selector switch to

run position.

2. if running with a dancer arm

control.

a. Check that the external/loop

switch is in the loop arm position.

3. if running with external control.

a. Check that the external/loop

arm switch is in the

external position.

4. Height switch setting too high.

a. Set height setting to “0”.

5. Percent speed pot set too low.

a. Adjust percent speed

pot to 100%.

6. Fuses blown.

a. Check fuses & circuit breaker.

7. no AC voltage at DC drive board.

a. Check wiring.

8. Check Signal voltage between

P2 to i2 on DC drive.

0-6 VDC—Ramm

0-9 VDC—Regen Drive

while moving dancer arm.

a. if there is a signal, check

continuity between i1 & i2.

b. if no continuity, replace D.C.

drive or call factory.

9. Check line voltage input of

69100034 board, 120 VAC, TB-1.

a. Check wiring. Call factory.

10. Check pico fuse 69100034

board (f1).

a. Replace fuse, 1 amp pico

fuse — call factory.

11. Check for 0-12 VDC between

pin #1 (=V) and pin #2 (GnD)

of panduit connector TC3 on

board #69100034.

a. if no voltage present, call

factory.

12. Check for DC voltage between

pin #6 (Vo) and pin #2 (GnD) of

panduit connector TC3, on board

69100034, while moving the dancer

arm from minimum to maximum

position.

a. if voltage is present, turn power

off and check the ribbon cable

connections between panduit

connector #TC3 of 69100034

board and panduit connector

#TB-4 of 69100076 board. This

should be a continuity check for

tight connections. Call factory

for assistance.

b. if voltage is not present move

on to step 13.

13. Check voltage between pin #5 of

TB-6 & pin #3 of TB-5 on 69100076

board while moving the dancer

arm from minimum to maximum

position.

a. if voltage varies 2.5-4 volt from

minimum to maximum position,

the dancer arm pot is oK, but

the 69100076 board could be

defective. Call factory.

b. if voltage does not vary when

moving the dancer arm from

minimum to maximum

position — call the factory

for assistance.

troubleShooting guide