The main pushbutton control box is

mounted on the top of the straight-

ener frame. Located on the face of the

console are eleven pushbuttons, one

display, one on/off switch, one circuit

breaker, one external loop plug and

inside the box is motor board and one

potentiometer when required, all of

which are explained below.

1. % SPEED POT

The % speed function adjusts the

maximum speed that the straightener

will feed and should be set to main-

tain a constant feed rate. Adjustable

in the run mode.

2. ON/OFF SWITCH

This illuminated switch is the main

power switch for the controller. It must

be “ON” for the machine to function.

3. RUN/STOP/JOG

SELECTOR SWITCH

This function selects between Run,

Stop and Jog. If in Run and the control

arm is moved the rolls will turn. If in

Jog, the Jog button has to be de-

pressed for the rolls to turn. If in Stop,

there should be no movement of the

rolls even if the dancer arm is raised

or lowered or the jog pushbutton is

pressed.

4. JOG BUTTON

Used for intermittent movement of

material on the rolls, mainly used for

set up or getting material thru the

straightener and over to the pulling

device. Active in jog mode only.

5. DANCER ARM LOOP HEIGHT

AND RANGE ADJUSTMENT

a. Loop Range – The loop range func-

tion adjusts the amount the dancer

arm will travel to provide the full

range of speed of the straightener.

There are eight positions available.

b. Loop Height – The loop height func-

tion is used for setting the start posi-

tion of the control arm. The setting de-

termines when the straightener rolls

will start turning. Each position will

move the operating start position up

from the home position to accom-

modate specific material rest height

requirements.

6. LOOP ARM / EXTERNAL SWITCH

This switch selects either dancer arm

(internal) by displaying “LV” for loop

arm vertical reel or “LH” for loop arm

horizontal reel (PMD) or external loop

control by displaying “RT” for the

RTB and ”RS” for the RS_1. The RLL

will work on the “RT” selection.

7. RESET BUTTONS

a. 15 amp – This is the main circuit

breaker for the 120 VAC input

straightener.

8. REMOTE INTERFACE

PORT “D” CONNECTOR

This connector is used to communi-

cate with external loop control equip-

ment.

CAUTION: Never plug any type of com-

puter or non Rapid-Air equipment into

this plug or severe damage will result.

Always consult with the factory when

installing new external controls for

compatibility and wiring information.

Start up procedure

Main Console And Controller

Prior to applying power to the machine the operator should review all the controls on the machine. A brief summary of the

controls is listed below.

Electrical Component Description

69100804 board - main reel control board

69100014 (RAMM) - D.C. motor board

29100021 dancer arm potentiometer

69100578 circuit breaker

69100315 rocker switch