Rapid-Air PALLET MASTER (PMDH): PMDH35 & PMDH50. 115VAC, 1PH, 60HZ User Manual

Page 5

Advertising
background image

5

Setting up the control

Turn on the main power switch and select “LH” for loop arm horizontal at “Loop Type” on
the pushbuttons.

Turn off the main power switch, press and hold the “Run/Stop/Jog” button while turning the
main power switch on. The first screen you see will display the jog speed percentage.
_________________________________
| JOG SPEED 23% + |
| NEXT - |
|_________________________________|

If you want the jog speed faster then press the “Reel Speed “+ “ “ pushbutton. If you want
the jog speed slower then press the “ Reel Speed “-” “ pushbutton. The jog speed is shown
in percent of max jog speed. If the jog speed is “OK “ then push the Run/Stop/Jog button
once for next.

The next screen asks if you want to set up the sensor? As before the percent speed buttons
are used for the yes-no. Select “yes”! And then next.
_________________________________
| SETUP SENSOR YES |
| NEXT NO |
|_________________________________|

The next screen asks you to set the low set point. If the dancer arm is at “No Material
Rest” then just save the setting by pushing the Stop/Run Jog pushbutton.
_________________________________
| SENSOR LOW SETPOINT |
| SAVE XXX |
|_________________________________|

The next screen is to set the offset of the program. Potentiometers are hard to get set from
left to right so we built in an offset. If you set the low and high range and go into run and
the reel runs for no reason then an offset has to be put in. Go through the setup procedure
again and put in an offset of –3 to –5 and now the pot is zero.

_________________________________
| LOW OFFSET +0 + |
| NEXT - |
|_________________________________|



Advertising