Reelcraft Series BA30000 Welding Hose Reels User Manual

Page 2

Advertising
background image

Series BA30000 Welding Hose Reels

Page 2

www.reelcraft.com

INSTALLATION INSTRUCTIONS

MOUNTING

Caution: Unless reel was specified differently when ordering,
maximum installation height is 16 feet. Do not exceed this dis-
tance. Observe all applicable NEC, OSHA & local codes when
installing this equipment.

1. Unpack and inspect reel for damage. Turn by hand to

check for smooth operation. Check for completeness.

2. Configure reel for top, side, or bottom-wind hose dispens-

ing by removing bolts (or nuts) (1) securing guide arm
bracket (2).

3. Determine new guide arm bracket location and remove

corresponding bolts, (or nuts). Position guide arm bracket
to reel and replace bolts (or nuts).

4. Position reel on floor, wall or ceiling. Secure into place

using four (customer supplied) screws or bolts (3).

INSTALLING THE INPUT HOSES

Caution: Apply teflon tape to all input connections to insure
a proper seal.

INSTALLING THE OUTPUT HOSES

Caution: Use extreme caution; reel under tension, avoid
releasing latch mechanism. Apply teflon tape to outlet connec-
tions.
1. Manually turn spool ass’y until spring is tight, back off

three turns, then latch.

2. Route output hoses through guide bracket.
3. Using a wrench, firmly hold on to fittings on shaft while

tightening the hose connector (see figure 1).

SERVICE INSTRUCTIONS

User servicing of the reel is limited to replacing the input/
output hoses or swivel only. Refer all other repairs to an autho-
rized service person or directly to Reelcraft Industries, Inc.
Failure to do so can result in personal injury and/or equipment
damage and may void the warranty.
Caution: Rewind hose on reel, then bleed pressure from sys-
tem before performing the following procedures.
1. Replace hoses in accordance with procedures given in

“Installation Instructions” section of this manual.

REPLACING THE SWIVEL

Caution: Remove supply line pressure before performing the
following procedure.
1. Remove supply line from swivel.
2. Remove swivel assembly from inlet shaft (see figure 2).
3. Apply thread sealant to threaded connection and re-install

swivel assembly to inlet shaft by reversing steps 1 & 2.

ADJUSTMENTS

Caution: Use extreme caution; reel under tension. Avoid
releasing latch mechanism. If necessary, adjust spring tension
of reel by adding or removing wraps of hose from spool, one
wrap at a time, until desired tension is obtained. Add wraps
to increase tension. Remove wraps to decrease tension. When
adding wraps of hose, be careful not to exceed the winding
mechanisms spring capacity. Add just enough wraps of hose to
achieve the desired tension. Damage to the winding mechanism
will result if spring is over-tensioned.

1

2

3

Acetylene/fuel gas
inlet 1/4” FPT
(Red)

Oxygen inlet
1/4” FPT (Green)

Figure 1

Figure 2

Advertising