Principle of pump operation, Model specific – Versa-Matic 2 Elima-Matic Metallic Food Processing – ATEX (E2 ) User Manual

Page 8

Advertising
background image

e2mdlCsmATEXFP-rev0514

www

.

versamatic

.

com

5

• Model E2 Metallic Food Processing

Air-Operated Double Diaphragm (AODD) pumps are powered

by compressed air or nitrogen.

The main directional (air) control valve

distributes

compressed air to an air chamber, exerting uniform pressure

over the inner surface of the diaphragm

. At the same time,

the exhausting air

from behind the opposite diaphragm

is directed through the air valve assembly(s) to an exhaust

port

.

As inner chamber pressure

(P1)

exceeds liquid chamber

pressure

(P2)

, the rod

connected diaphragms shift

together creating discharge on one side and suction on the

opposite side. The discharged and primed liquid’s directions

are controlled by the check valves (ball or flap)

orientation.

The pump primes as a result of the suction stroke. The

suction stroke lowers the chamber pressure

(P3)

increasing

the chamber volume. This results in a pressure differential

necessary for atmospheric pressure

(P4)

to push the fluid

through the suction piping and across the suction side check

valve and into the outer fluid chamber

.

Suction (side) stroking also initiates the reciprocating

(shifting, stroking or cycling) action of the pump. The suction

diaphragm’s movement is mechanically pulled through its

stroke. The diaphragm’s inner plate makes contact with an

actuator plunger aligned to shift the pilot signaling valve.

Once actuated, the pilot valve sends a pressure signal to the

opposite end of the main directional air valve, redirecting the

compressed air to the opposite inner chamber.

Principle of Pump Operation

SAFE AIR

EXHAUST

DISPOSAL

AREA

PUMP INSTALLATION AREA

1" DIAMETER AIR

EXHAUST PIPING

1" DIAMETER AIR

EXHAUST PIPING

1" DIAMETER AIR

EXHAUST PIPING

MUFFLER

LIQUID

LEVEL

SUCTION

LINE

LIQUID

LEVEL

SUCTION

LINE

MUFFLER

MUFFLER

SUBMERGED ILLUSTRATION

Pump can be submerged if the pump materials of construction

are compatible with the liquid being pumped. The air exhaust

must be piped above the liquid level. When the pumped product

source is at a higher level than the pump (flooded suction

condition), pipe the exhaust higher than the product source to

prevent siphoning spills.