Performance, Materials, Material profile – Versa-Matic 2 Elima-Matic 3-A Certified (E2 ) User Manual

Page 5: Metals, Pump specs

Advertising
background image

e2mdlCsm3A-rev0714

www

.

versamatic

.

com

Model E2 3-A Sanitary •

2

Performance

E2 - 2” 3-A Sanitary Pump – Metallic Center

PTFE FITTED

Flow Rate

Adjustable to . . . . . . . 0-147 gpm (556 lpm)

Port Size

Suction . . . . . . . . . . . . . . . . . 2" TRI-CLAMP

Discharge. . . . . . . . . . . . . . . 2" TRI-CLAMP

Air Inlet . . . . . . . . . . . . . . . . . . . . . . 1/2" NPT

Air Exhaust . . . . . . . . . . . . . . . . . . . 1" NPT

Suction Lift

Dry . . . . . . . . . . . . . . . . . . . . . . . . .9' (2.7 m)

Wet. . . . . . . . . . . . . . . . . . . . . . . .27' (8.2 m)

Max Solid Size (Diameter)

. . . . . . . . . . . . . . . . . . . . . . . 5/8" (15.8 mm)

Max Noise Level . . . . . . . . . . . . . 98 dB(A)

Shipping Weights

Stainless. . . . . . . . . . . . . . .125 lbs (56.7 kg)

Discharge Head in PSI

0

140

120

100

80

60

40

20

0

Capacity in Liters Per Minute

Capacity in U.S. Gallons Per Minute

Capacity Per Stroke, 0.35 Gal. (1.32 L)

AIR CONSUMPTION IN SCFM

AIR PRESSURE IN PSI

SCFM M3/HR

10

17

20

34

40

68

60

102

80

136

100

170

120

204

140 240

0

20

80

160

240

320

400

480

560

640

10 20 40

60 80

100

120

140

40

60

80

100

120

140

160

Meters Feet

0

0

40

80

120

160

200

240

280

10

20

30

40

50

60

80

90

70

NOTE: Performance based on the following: elastomeric fitted pump, flooded suction, water at

ambient conditions. The use of other materials and varying hydraulic conditions may result in

deviations in excess of 5%.

Materials

Material Profile:

Operating

Temperatures:

Max.

Min.

Virgin PTFE: (PFA/TFE) Chemically inert, virtually impervious.

Very few chemicals are known to chemically react with PTFE;

molten alkali metals, turbulent liquid or gaseous fluorine and

a few fluoro-chemicals such as chlorine trifluoride or oxygen

difluoride which readily liberate free fluorine at elevated

temperatures.

220°F

104°C

-35°F

-37°C

Maximum and Minimum Temperatures are the limits for which these materials can be operated.

Temperatures coupled with pressure affect the longevity of diaphragm pump components.

Maximum life should not be expected at the extreme limits of the temperature ranges.

Metals:

Stainless Steel: Equal to or exceeding ASTM specification A743 CF-8M for corrosion

resistant iron chromium, iron chromium nickel and nickel based alloy castings for

general applicaitons. Commonly referred to as 316 Stainless Steel in the pump industry.

For specific applications, always consult the Chemical Resistance Chart.

CAUTION! Operating temperature limitations are as follows:

1: PUMP

SPECS

Advertising