Performance, Pump specs – Versa-Matic 2 Elima-Matic Sanitary - ATEX (E2 ) User Manual
Page 6
e2mdlCsmATEXS-rev0514
www
.
versamatic
.
com
3
• Model E2 Sanitary
Performance
E2 - 2” Sanitary Pump – Metallic Center
TPE FITTED
Flow Rate
Adjustable to . . . . . . . 0-179 gpm (677 lpm)
Port Size
Suction . . . . . . . . . . . . . . . . . 2" TRI-CLAMP
Discharge. . . . . . . . . . . . . . . 2" TRI-CLAMP
Air Inlet . . . . . . . . . . . . . . . . . . . . . . 1/2" NPT
Air Exhaust . . . . . . . . . . . . . . . . . . . 1" NPT
Suction Lift
Dry . . . . . . . . . . . . . . . . . . . . . . . .15' (4.6 m)
Wet. . . . . . . . . . . . . . . . . . . . . . . .32' (9.8 m)
Max Solid Size (Diameter)
. . . . . . . . . . . . . . . . . . . . . . . 5/8" (15.8 mm)
Max Noise Level . . . . . . . . . . . . . 98 dB(A)
Shipping Weights
Stainless. . . . . . . . . . . . . . .125 lbs (56.7 kg)
E2 - 2” Sanitary Pump – Metallic Center
PTFE FITTED
Flow Rate
Adjustable to . . . . . . . 0-147 gpm (556 lpm)
Port Size
Suction . . . . . . . . . . . . . . . . . 2" TRI-CLAMP
Discharge. . . . . . . . . . . . . . . 2" TRI-CLAMP
Air Inlet . . . . . . . . . . . . . . . . . . . . . . 1/2" NPT
Air Exhaust . . . . . . . . . . . . . . . . . . . 1" NPT
Suction Lift
Dry . . . . . . . . . . . . . . . . . . . . . . . . .9' (2.7 m)
Wet. . . . . . . . . . . . . . . . . . . . . . . .27' (8.2 m)
Max Solid Size (Diameter)
. . . . . . . . . . . . . . . . . . . . . . . 5/8" (15.8 mm)
Max Noise Level . . . . . . . . . . . . . 98 dB(A)
Shipping Weights
Stainless. . . . . . . . . . . . . . .125 lbs (56.7 kg)
Discharge Head in PSI
0
140
120
100
80
60
40
20
0
Capacity in Liters Per Minute
Capacity in U.S. Gallons Per Minute
Displacement Per Stroke, 0.60 Gal. (2.27 L)
AIR CONSUMPTION IN SCFM
AIR PRESSURE IN PSI
SCFM M3/HR
10
17
20
34
40
51
60
102
80
136
100
170
120
204
140 240
0
20
80
160
240
320
400
480
560
640
720
10 20
40
60
80
100
120
140
40
60
80
100
120
140
160
180
200
Meters Feet
0
0
40
80
120
160
200
240
280
320
10
20
30
40
50
60
80
90
70
0
1
2
3
4
5
6
7
8
9
10
BAR
Discharge Head in PSI
0
140
120
100
80
60
40
20
0
Capacity in Liters Per Minute
Capacity in U.S. Gallons Per Minute
Capacity Per Stroke, 0.35 Gal. (1.32 L)
AIR CONSUMPTION IN SCFM
AIR PRESSURE IN PSI
SCFM M3/HR
10
17
20
34
40
68
60
102
80
136
100
170
120
204
140 240
0
20
80
160
240
320
400
480
560
640
10 20 40
60 80
100
120
140
40
60
80
100
120
140
160
Meters Feet
0
0
40
80
120
160
200
240
280
10
20
30
40
50
60
80
90
70
NOTE: Performance based on the following: elastomeric fitted pump, flooded suction, water at
ambient conditions. The use of other materials and varying hydraulic conditions may result in
deviations in excess of 5%.
NOTE: Performance based on the following: elastomeric fitted pump, flooded suction, water at
ambient conditions. The use of other materials and varying hydraulic conditions may result in
deviations in excess of 5%.
1: PUMP