Innotech Systems SpitFIRE II User Manual

Page 14

Advertising
background image

SpitFIRE

Innotech Systems Inc.

Page 14

1 0 Visible LED flash count

1 1 Status message

DAT3-0

Status messages (MOD=11)

0000 NOP

0001 This scancode is not currently used

0010 The selected device number is not in the database

0011 This button is not implemented on the selected device.

0100 No source programmed

0101 Programming sequence aborted

0110 IR transmission complete

0111 Database error

1000 SpitFIRE has been reset

1001 Auto search mode

1010 No learn location specified

1011 No IR detected in learn mode

1100 Press button to specify learn location

1110 Invalid code

1111 Could not learn button

DAT3-0

LED flashes in BCD (0-9)

DAT3-0

Software revision code (0-31) Uses MOD0 as a 5th bit.

For example, assume that a VCR was previously programmed as Source 1. To select the source and

press the POWER button:

System sends

C1h

Select VCR (source #1)

System gets

21h

Return 1 flash

System sends

D2h

Transmit IR 2 times mode

System gets

21h

Return 1 flash

System sends

96h

Press the POWER button

System gets

36h

IR Transmission complete (after a delay)

The source selection and transmission instructions stay in effect until they are changed.

Advertising