Ross Controls INLINE GENERAL PURPOSE & LEAK TEST SERIES LX User Manual

Series lf, lx solenoid pilot controlled valves

Advertising
background image

18

© 2010, ROSS CONTROLS

®

.

All Rights Reserved.

Series LF, LX Solenoid Pilot Controlled Valves

Single Solenoid Pilot Controlled, Spring Assisted Air Return
2/2 Valves

1

2

1

2

Normally Open (NO)

Normally Closed (NC)


Port Sizes

Valve Model Number*

Avg.

Dimensions inches (mm)

Weight

1

2

NC

NO

C

V

Length

Width

Height NC

Height NO

lb (kg)

3/8 3/8

LF13NA37101W LF23NA37101W

3.6

3.12 (79.4) 1.88 (47.7) 4.81 (122.2)

5.45 (138.4)

1.5 (0.7)

1/2 1/2

LF14NA47101W LF24NA47101W

3.6

3.12 (79.4) 1.88 (47.7) 4.81 (122.2)

5.45 (138.4)

1.5 (0.7)

3/4 3/4

LF15NA57101W LF25NA57101W

12.2

4.12 (104.7)

2.50 (63.5) 6.96 (176.8)

7.30 (185.4)

3.5 (1.6)

1

1

LF16NA67101W LF26NA67101W

12.2

4.12 (104.7)

2.50 (63.5) 6.96 (176.8)

7.30 (185.4)

3.5 (1.6)

11/4 11/4

LF17NA77101W LF27NA77101W

36.1

9.12 (231.7)

3.75 (95.3) 5.50 (139.7)

9.46 (240.3) 9.3 (4.2)

11/2 11/2

LF18NA87101W LF28NA87101W

36.1

9.12 (231.7)

3.75 (95.3) 5.50 (139.7)

9.46 (240.3)

9.3 (4.2)

2

2

LF19NA97101W LF29NA97101W

64.7

10.72 (272.2) 5.00 (127.0) 7.50 (190.5) 10.99 (279.1) 19.3 (8.8)

21/2 21/2

LF10NA07101W LF20NA07101W

64.7

10.72 (272.2) 5.00 (127.0) 7.50 (190.5) 10.99 (279.1) 19.3 (8.8)

STANDARD SPECIFICATIONS:
For Series LF, LX Solenoid Pilot Controlled Valves.
Pilot Solenoid: AC or DC power. Rated for continuous duty. Voltage
and hertz ratings shown on pilot housing.
Standard Voltages: 24 volts DC; 120 volts AC 50/60 Hz.
Power Consumption:
Port size 3/8” and 1/2” inlet: 9.8 VA on AC; 7.5 watts on DC.
Port size 3/4 thru 2

1/2” inlet: 36 VA inrush, 23 VA holding on AC;

15 watts on DC.
Ambient Temperature: 40° to 120°F (4° to 50°C).

Media Temperature: 40° to 175°F (4° to 80°C).
Flow Media: Filtered air; 5 micron recommended.
Inlet Pressure: Vacuum to 145 psig (10 bar), (vacuum service
requires external pilot supply).
Pilot Pressure: 30 to 145 psig (2 to 10 bar). Must be equal to or
greater than inlet pressure. For vacuum service models requiring
external pilot supply, a pilot pressure of at least 30 psig (2 bar) is
required.
Port Threads: NPT, BSPP.

Note: For fluid applications, consult ROSS.

IMPORTANT NOTE: Please read carefully and thoroughly all of the CAUTIONS on the inside back cover.

* For models with external pilot supply, replace shaded “1” in the model number with a “5”, e.g., LF13NA37501Z.
For BSPP threads, replace “N” in the model number with a “D”, e.g., LF13DA37101W.
For 120 volts AC, 50/60 Hz, replace suffix “W” with “Z”, e.g., LF13NA37101Z.
Electrical connectors not included, see below for accessories.

Part Numbers of Electrical Connectors

Valve Port

Lighted Connector Only

Lighted Connector Pre-wired*

Size

24 volts DC 110 Volts AC

24 volts DC

110 Volts AC

NC 3/8, 1/2

267K77W

267K77Z

382K77W

382K77Z

NO 3/8 - 1

267K77W

267K77Z

382K77W

382K77Z

NC 3/4 - 21/2

936K87W

936K87Z

720K77W

720K77Z

NO 11/4 - 21/2

936K87W

936K87Z

720K77W

720K77Z

*Pre-wired connectors are lighted and include a 2 meter (61/2 ft.) cord.

ELECTRICAL CONNECTORS:

For Series LF, LX Solenoid Pilot Controlled Valves.

Advertising