Serial bus system, Valve driver module, Power extender module – Ross Controls ROSS MODULAR I User Manual

Page 37: Terminating base module, Bus extender cable, Devicebus terminating resistor

Advertising
background image

37

www.rosscontrols.com

Valve Driver Module

32 Point Module – Size 00, 0, 1, 2, & 3

RPSSV32A*

24 Output Cable – Size 00 & 0

RPS5624P

25 - 32 Output Cable – Size 00 & 0

RPS5632P

24 Output Cable – Size 1, 2, & 3

RPS4024P

Power Extender Module

24VDC Field Power Module

RPSSSE24A

24VDC

Terminating Base Module

Terminating Module

RPSSTERM

RPSSV32A

RPSSTERM

RPSSSE24A

Bus Extender Cable

1 Meter Cable*

RPSSEXT1

24VDC

3 Meter Cable*

RPSSEXT2

24VDC

* Requires a RPSSSE24A Power Extender Module.

IP67 Certified

See www.rosscontrols.com

RPSSEXT1

A Power Extender Module must be used on every 12th Module in an Serial Bus
assembly. See www.rosscontrols.com

Reference Document A10317 and A10311 for configuration instructions. See
www.rosscontrols.com

Used as the last Terminating Module for a Stand Alone Serial Bus Assembly.

A RPSST8M23A must be located in the Serial Bus assembly.

* Reference Document A10312 for Installation Instructions.

See www.rosscontrols.com

† Serial Bus Manifold assemblies and end plate kits include a valve driver module

(RPSSV32A) and cable.

Series W66, Size 00 / Series W66, Size 0 24 output manifolds require a

RPS5624P.

Series W66, Size 00 / Series W66, Size 0 32 output manifolds require a

RPS5624P + RPS5632P.

Size 1, 2, & 3 manifolds require a RPS4024P, allowing 21 outputs.

Devicebus Terminating Resistor

DeviceNet™ M12 Type A

RP8BPA00MA

Profibus-DP M12 Type B

RP8BPA00MB

RP8BPA00MA

Serial Bus System