Modular l-o-x, Air entry combination, How to order – Ross Controls MODULAR WITH INTEGRATED FILTER User Manual

Page 3: Flow to 105 scfm, Dimensions inches (mm), Ab c

Advertising
background image

2

© 2012,

ROSS CONTROLS

®

. All Rights Reserved.

GAUGE
A - No Gauge
B - (0-200 psig)
C - (0-60 psig)
D - No Gauge with Panel Mount Nut
E - (0-200 psig) Gauge with Panel Mount Nut
F - (0-60 psig) Gauge with Panel Mount Nut

ADJUSTMENT RANGE
A - 0-150 psig (0-10 bar); reverse flow
B - 0-100 psig (0-6.8 bar); standard, reverse flow
C - 0-50 psig (0-3.4 bar); reverse flow

PIPE SIZE
2 - 1/4 NPTF
3 - 3/8 NPTF
4 - 1/2 NPTF
C - 1/4 BSPP
D - 3/8 BSPP
E - 1/2 BSPP

MD3

53P

B

A

B

5

B

B –

BOWL SIZE
53P - Polycarbonate Bowl (4 oz)
53M - Metal Bowl with sight gauge (6 oz)

ELEMENT TYPE
A - 40 Micron
B - 5 Micron; standard

BOWL DRAIN
A - Auto Drain/Differential Pressure
M - Manual Drain
F - Float Drain (metal bowl only)

ADD ON L-O-X

®

1 - Outlet Side
2 - Inlet Side
3 - L-O-X

®

with EEZ-ON

®

on Outlet Side

4 - L-O-X

®

with EEZ-ON

®

on Inlet Side

X - no L-O-X

®

HOW TO ORDER

DIMENSIONS inches (mm)

Weight

Bowl

A

B *

C **

Depth

lb (kg)

Polycarbonate 7.7 (195.6) 4.81 (122.2) 3.23 (82.0) 2.9 (73.7) 3.12 (1.4)

Metal

7.7 (195.6) 6.43 (163.4) 3.23 (82.0) 2.9 (73.7) 3.18 (1.4)

* Bowl removal clearance: add 3.1 (79).
** Dome removal clearance: add 0.63 (16).
† Less gauge.

Ports: 1/4, 3/8, 1/2

Flow to 105 scfm

REPLACEMENT FILTER ELEMENT KITS

Element Rating

Kit Number

5-µm (Std. element) ................................936K77
40-µm

..........................................938K77

Accessories not included with the product, see page 4
for ordering information.

FILTER/REGULATOR FLOW CHARACTERISTICS

Modular L-O-X

®

Air Entry Combination

A

B

C

0

50

100

150

200

250

scfm

l/s 0

25

50

75

100

0

psid

DIFFERENTIAL PRESSURE

0.5

1

1.5

2

2.5

3

3.5

4

4.5

5

0

bar

0.03

0.06

Inlet pressure psig (bar)

36 (2.5)

92 (6.3)

145 (10.0)

0.10

0.14

0.17

0.21

0.24

0.28

0.31

0.34

1/4 Ports

0

50

100

150

200

250

scfm

l/s 0

25

50

75

100

0

psid

DIFFERENTIAL PRESSURE

0.5

1

1.5

2

2.5

3

3.5

4

4.5

5

0

bar

0.03

0.06

Inlet pressure psig (bar)

36 (2.5)

92 (6.3)

145 (10.0)

0.10

0.14

0.17

0.21

0.24

0.28

0.31

0.34

3/8 Ports

0

50

100

150

200

250

scfm

l/s 0

25

50

75

100

0

psid

DIFFERENTIAL PRESSURE

0.5

1

1.5

2

2.5

3

3.5

4

4.5

5

0

bar

0.03

0.06

Inlet pressure psig (bar)

36 (2.5)

92 (6.3)

145 (10.0)

0.10

0.14

0.17

0.21

0.24

0.28

0.31

0.34

1/2 Ports

0

10

scfm

FLOW

l/s 0

5

20

psi

100

OUTLET PRESSURE

1.4

2.8

4.2

5.6

bar
7.0

INLET PRESSURE: 91 psig (6.3 bar)

0

scfm

FLOW

l/s 0

0

0

20

30

40

50

60

70

80

90

100 110

10

15

20

25

30

35

40

45

50

1/2 Ports

1/4 Ports

3/8 Ports

40

60

80

20

psi

100

OUTLET PRESSURE

1.4

2.8

4.2

5.6

bar
7.0

0

0

40

60

80

20

psi

100

OUTLET PRESSURE

1.4

2.8

4.2

5.6

bar
7.0

0

0

40

60

80

LOCKOUT VALVE FLOW CHARACTERISTICS

Advertising