# Voltage Monitoring:

Click <Enter> key to enter its submenu:

All Voltages:

These items display the voltage of each element.

! Shutdown Enable:

Use <Space> key to enable system shutdown function. If the voltage of corresponding element is
higher/lower than the high/low limit, the system would automatically shutdown.

! Beep Enable:

Use <Space> key to enable warning beeps function. If the voltage of corresponding element is
higher/lower than the high/low limit, warning beeps will sound.

! High/Low Limit:

These items set the high and low voltage limit.

NOTE: The value of high limit must be set above the one of low limit.