Local Setup Setting

This parameter determines whether the OIT allows you to access Configuration mode. If

this parameter is disabled, you will not be able to enter Configuration mode. Since you

must enter Configuration mode to reprogram the OIT, you will not be able to reprogram

the OIT until the host controller sends a Keyboard control command enabling local setup

again.
Factory Default: Enabled
To modify this parameter using STEPware-100:
1. Open the Configuration Editor.

2. In the OIT Operational Settings group box, select the Local Setup Enabled check box.
To modify this parameter in Configuration mode:
1. At Setup Access:, use the OIT’s Period (.) key to enable or disable local setup. Refer

to the Configuration Mode section in this chapter for more information.

To modify this parameter from the host controller:
1. Use the Keyboard control command. Refer to Appendix A: Control Commands for

more information.

Passwords Setting

This parameter determines the five-digit numeric password used to restrict entry into

Configuration mode. Configuration mode is used to change the OIT’s operating

parameters or to download/upload a project to/from STEPware-100.
When attempting to enter Configuration mode, the OIT prompts you to enter the Setup

Password. If the default setting of “00000” has not been changed, you simply press the

OIT’s ENTER key to access Configuration mode. If the setup password has been changed,

you must enter the correct five-digit numeric password to access Configuration mode.

NOTE:If you forget your password, call Maple Systems Technical Support department at

425-745-3229 for help accessing Configuration mode.

Factory Default: 00000
To modify this parameter using STEPware-100:
1. Open the Configuration Editor.
2. In the OIT Operational Settings group box, choose the Editor button to open the Password

Editor dialog box.

3. In the Setup text box, enter a five-digit numeric password.
4. Choose the Done button.
To modify this parameter in Configuration mode:
1. At Setup Password, use the OIT’s numeric keys to enter a five-digit numeric

password. Refer to the Configuration Mode section in this chapter for more

information.

To modify this parameter from the host controller:
1. This feature cannot be changed from the host controller.

17

MAP450D Operation Manual

1010-0101, Rev. 00