Age.16), Rs-232c – Proface GP4600R - 12.1 Standard HMIs with Rear Mounting Options" User Manual

Page 15

Advertising
background image

16

Eng

lis

h

Interface

2. RS-232C

D-Sub 9 pin plug connector via an RS-232C cable.

Note: (1) You can switch pin #9 between RI and VCC via software. To prevent damage or
a unit malfunction, use only the rated current.

Interfit bracket is #4-40 (UNC).
Recommendations:

Cable Connector: XM2D-0901 manufactured by OMRON Corporation.

Cable Cover: XM2S-0913 manufactured by OMRON Corporation.

Jack Screw (#4-40 UNC): XM2Z-0073 manufactured by OMRON
Corporation.

Pin
Number

RS-232C
Signal Name

Direction

Meaning

1

CD

Input

Carrier Detect

2

RD(RXD)

Input

Receive Data

3

SD(TXD)

Output

Send Data

4

ER(DTR)

Output

Data Terminal Ready

5

SG

Signal Ground

6

DR(DSR)

Input

Data Set Ready

7

RS(RTS)

Output

Request to Send

8

CS(CTS)

Input

Send Possible

9

CI(RI)/VCC

Input/–

Called Status Display
+5V

±5% Output 0.25A

(1)

Shell

FG

Frame Ground (Common
with SG)

Advertising