Definitions of functions, parameters and values, Configuration mode – Watlow MINICHEF 2000 User Manual

Page 45

Advertising
background image

D e f i n i t i o n s o f F u n c t i o n s , P a r a m e t e r s a n d Va l u e s

4 4

Wa t l o w M

I N I

C

H E F

2 0 0 0

H a r d w a r e & S o f t w a r e S e t u p G u i d e

Definitions of Functions, Parameters and Values

Configuration Mode

[etype] Equipment Type Function
Configures control for application and sounds.

[APPl`] Application Number
Selects the application software set for the controller.
Range: 1-20 Default: 20

[a_Loc] Application Number Security Lock
Choose between [``yes] and [```no] to lock the Application Number. When [a_Loc]
is set to [``yes], the Application Number is not adjustable.
Range: [``yes], [```no] Default: [```no]

[Ptine] Pressure Release Time
Sets the number of seconds before the completion of a menu when the pressure output
is released.
Range: 1-120 sec. Default: 60

[Sound]] Audible Alarm Sound
Type of audible alarm that will sound at the completion of a menu cycle or at the end of
a hold cycle.
Range: 0-5 Default: 0
0 = no alarm sound at the end of menu
1 = alarm sounded for 2 seconds
2 = alarm sound alternatives on/off every second for 20 seconds
3 = 3 short beeps followed by 1 second off, this cycle repeats itself for 20 seconds
4 = alarm sounds on/off every second continuously
5 = alarm is on solid, continuously

Note: All alarms can be silenced by pressing the appropriate key once.

[btine] Basket Travel Time
This is the number of seconds that the output for basket lift/drop will be on. This
prompt is only visible on applications with automatic basket lift.
Range: 0 - 30 seconds Default: 2 seconds

[preHT] Preheat Temperature
The temperature that the control will preheat to upon power-up. This prompt is only
visible on some deep fat fryer applications.
Range: temp range low - range high Default: temperature range low

[idLE1] Idle Temperature Number 1
This is the effective setpoint when you press the idle one key. This idle setpoint can only
be regulated to during the idle state.
Range: temp range low - range high Default: temperature range low

Advertising