Programming, Chapter 5

WATLOW Series 942 User's Manual

37

Figure 37 -
Guaranteed Soak
Deviation Example

Jumploop

Time

Guaranteed Soak
Deviation Window
Around Set Point

Set Point

Set Point

Multiple Profiles

The Series 942 is a single profile control, but can be programmed for multiple
profiles. To do this, enter your first profile; the next step you enter following the
End step is the start of another profile. You can continue entering profiles until you
run out of steps, remember there are a total of 24 steps.

Jumploop

The Series 942 can only jump backwards. A jump forces you to a step already
performed. The Jump Step (JS) must be less than the current step. You cannot
jumploop to the step that you are on.

Step 2

StPt

Step 3

StPt

Step 4

StPt

Step 5

Jumploop

JS - 02

JC - 01

Step 6

End

Your Jump Count (JC) can be anything from 0 - 100. If you enter 0, this will be an
infinite loop and never progresses to Step 6.