Watlow SpecView from Watlow User Manual

Page 32

Advertising
background image

SpecView from Watlow

 32 

Watlow Addendum

2) With SpecView

running, to enter the
configuration mode,
from the File menu
choose
Configuration Mode.

3) Click

to open the

Variables list.

4) Select the instrument.

5) Click Properties.

6) In the Address field

set the decimal places
corresponding to the
controller setting
0 for whole numbers,
1 for tenths,
2 for hundredths,
3 for thousandths
4 for ten-thousandths:

• For Modbus RTU

protocol set the
number after the
comma.

• For Modbus TCP or

Anafaze/AB protocols
set the number after
the second comma.

7) Click Rename Only.

Modbus RTU: the decimal setting is after the comma

Modbus TCP: the decimal setting is after the second comma

8) To save the GDW:

• From the File menu,

choose Save.

Note: The possible decimal settings may depend on other controller settings such as the sensor type.

Not all parameters are affected by the decimal setting.