CAUTION: Maintenance

DISASSEMBLY
1.

Replacement parts may be available at the store where you purchased
your faucet.

2.

When replacement parts are not available, please write or call Price Pfister
Consumer Service.

3.

Always turn off water and relieve pressure before working on your
faucet.

NOTE: Trim Care

Cleaning Instructions:
For all Handles and decorative finishes, use only a soft damp cloth
to clean and shine. Use of polish, detergents, abrasive cleaners,
organic solvents or acid may cause damage. Use of other than
a soft damp cloth will nullify our warranty!
Special Trim:

Trim products which contain Porcelain or other similar substance
are not acceptable for public areas or Commercial use. Installation
of Said Trim is at Users Risk!

1–800–PFAUCET (1–800–732–8238)

For Toll-Free Pfaucet information call
1–800–PFAUCET (1–800–732–8238)
or visit www.pricepfister.com

• Installation Support
• Care and Warranty Information

14 UNIT START UP

Turn on hot and cold water supplies, and check for leaks above and below the sink.

15 FAUCET FUNCTION

COLD valve: close-counterclockwise, open-clockwise; HOT valve: close-clockwise,
open-counterclockwise.

16 HANDLE REMOVAL

Turn off water supplies and relieve pressure before working on your faucet
(see step 2). With valves in closed position, detach Decorative Button (16A), unscrew
Fastener (16B), and Handle Hub (16C) from Valve Stem (16D). Remove Valve Flange
(16E), Seal Base (16F) and Plastic Nut (16G). Unscrew Retainer Nut (16H) by turning
it counter-clockwise and lift out Cartridge Assembly (16J) and inspect. Replace parts
as necessary.

5

OPEN

OPEN

HOT

COLD

16A

16B

16C

16G

16F

16E

16H

16D

16J