<7. Operation of EJXMVTool>

7-20

IM 01C25R51-01E

Table 7.12

Symbol

#

Symbol

Description

1

Qm

Mass Flow

2

Qv

Volume Flow

3

Qv_norm

Normal·Standard Volume Flow

4

Nc

Unit convert factor

5

Kfactor

Basic flow Calculation factor

6

C

Discharge Coefficient

7

ε

Expansion Factor

8

β

Diameter Ratio

9

d

Diameter of orifice

10

∆p

Differential Pressure

(Transmitter Setting unit)

11

ρb

Base Density on Tb, SPb Condition

12

ρnorm

Density on Normal, Standard condition

13

Tb

Reference temperature unit: K

14

T

Temperature unit: K

15

SPb

Reference static pressure unit: kPa abs

16

SP

Static Pressure unit: kPa abs

17

Temp K1

The density rate of change per temperature 1degC of a density base value

(value which set 100% to 1)

For volume flow: set 0.

18

K

Compressibility factor

(2) Liquid

Figure 7.20 Basic Mode Setup for Liquid

• Input Reference Temperature (Tb), Kfactor, Temp K1
• Input Reference static pressure to 0. (This factor is used for gas)

NOTE

Reter to IM01C25R01-01E for the calculation of these flow factors.