Yokogawa EJX930A User Manual

Page 44

Advertising
background image

<5. Modbus Communication>

5-13

IM 01C25R05-01EN

Address Label used in

DTM

Address Type Access Type

Char/

Date

Read/

Write Enum list

Default

Value

*1

Unit

Valid

Range

IM

Chapter

1947

Disp User Value

Point 15

Holding

Register

USIGN8

-

W

Table 88

0x0001

-

0 to 4

3.4.3

1948

Disp User Value

Point 16

Holding

Register

USIGN8

-

W

Table 88

0x0001

-

0 to 4

3.4.3

2001

Engr Select

Holding

Register

USIGN8

-

W

Table 89

0x0000

-

0 to 2

3.4.3

2002-

2005

Engr Unit

Holding

Register

USIGN32×2

ASCII

W

-

spaces

-

-

3.4.3

2006

Engr exp

Holding

Register

USIGN8

-

W

Table 90

0x0000

-

0 to 3

3.4.3

2007

Engr URV

Holding

Register

FLOAT

-

W

-

100.0

-

-

3.4.3

2009

Engr LRV

Holding

Register

FLOAT

-

W

-

0.0

-

-

3.4.3

2011

Engr point

Holding

Register

USIGN8

-

W

Table 88

0x0001

-

0 to 4

3.4.3

2012

Set Engr Unit

Holding

Register

USIGN8

-

W

Table 91

0x0000

-

0 to 45

3.4.3

2051

Pres Alert Mode Holding

Register

USIGN8

-

W

Table 92

0x0000

-

0 to 3

3.4.7

2052

Pres Hi Alert Val Holding

Register

FLOAT

-

W

-

100.0

kPa

-110 to

110

3.4.7

2054

Pres Lo Alert Val Holding

Register

FLOAT

-

W

-

-100.0

kPa

-110 to

110

3.4.7

2056

SP Alert Mode

Holding

Register

USIGN8

-

W

Table 92

0x0000

-

0 to 3

3.4.7

2057

SP Hi Alert Val

Holding

Register

FLOAT

-

W

-

25.0

MPa

-2.5 to

27.5

3.4.7

2059

SP Lo Alert Val

Holding

Register

FLOAT

-

W

-

0.0

MPa

-2.5 to

27.5

3.4.7

2061

ET Alert Mode

Holding

Register

USIGN8

-

W

Table 92

0x0000

-

0 to 3

3.4.7

2062

ET Hi Alert Val

Holding

Register

FLOAT

-

W

-

850.0

°C

-200 to

850

3.4.7

2064

ET Lo Alert Val

Holding

Register

FLOAT

-

W

-

-200.0

°C

-200 to

850

3.4.7

2101

Flow Simulation

Mode

Holding

Register

USIGN8

-

W

Table 93

0x0000

-

With in

enum list

3.4.8

2102

Flow Sim Pres

Unit

Holding

Register

USIGN8

-

W

Table 60

0x000C

-

With in

enum list

3.4.8

2103

Flow Sim Pres

Holding

Register

FLOAT

-

W

-

0.0

kPa

-1600 to

1600

3.4.8

2105

Flow Sim SP

Unit

Holding

Register

USIGN8

-

W

Table 61

0x000C

-

With in

enum list

3.4.8

2106

Flow Sim SP

Holding

Register

FLOAT

-

W

-

0.0

kPa

-400000

to 400000

3.4.8

2108

Flow Sim Temp

Unit

Holding

Register

USIGN8

-

W

Table 62

0x0023

-

With in

enum list

3.4.8

2109

Flow Sim Temp Holding

Register

FLOAT

-

W

-

273.15

K

-

3.4.8

2111

Sim Device

Variable Code

Holding

Register

USIGN8

-

W

Table 94

0x0001

-

1 to 3

3.4.8

2112

Sim Write

Device Variable

Code

Holding

Register

USIGN8

-

W

Table 95

0x0000

-

0 to 1

3.4.8

2113

Sim Unit Code

Holding

Register

USIGN8

-

W

Table

60, 61, 62

0x0000

-

With in

enum list

3.4.8

2114

Sim Device

Variable Value

Holding

Register

FLOAT

-

W

-

0.0

-

-

3.4.8

2116

Sim Device

Variable Status

Holding

Register

USIGN8

-

W

Table 5

0x0000

-

With in

enum list

3.4.8

2117

Test Auto

Release Time

Holding

Register

USIGN8

-

W

Table 96

0x0000

-

0 to 5

3.4.8

*1:

This value is factory default of M range measurement span without order specification.

*2:

Upper case character can be used. Lower-case is translated to upper case.