3 error description and countermeasure, Error description and countermeasure -6 – Yokogawa ADMAG AXF User Manual

Page 82

Advertising
background image

IM 1E10C1-E

8-6

8. ACTUAL OPERATON

8.2.3

Error Description and Countermeasure

Display detail

BRAIN Terminal

HART Communicator

Indicator

of SE

Description

Countermeasure

---

GOOD

---

ERROR

Err-02 uP FAULT

Err-03 EEPROM FAULT

Err-05 A/D FAULT

Err-06 SIGNAL

OVERFLOW

Err-07 COIL OPEN

Err-08 SPAN VEL.>10m/s

Err-09 SPAN VEL.<0.3m/s

Err-10 P.SPAN>1000p/s

Err-11 P.SPAN>500p/s

Err-12 P.SPAN>25p/s

Err-13 P.SPAN>15p/s

Err-14 P.SPAN>10p/s

Err-15 P.SPAN>5p/s

Err-16 P.SPAN<.0001p/s

Err-17 T.SPAN>1000p/s

Err-18 T.SPAN>.0001p/s

Err-19 4-20 LMT ERROR

Err-20 EMPTY PIPE

Err-21 MULTIRANGE

ERROR

Err-22 COIL SHORT

Err-23 EEPROM NO SET

Err-24 EEPROM

DEFAULT

Err-25 ---

Self test OK

Error

uP fault

EEPROM fault

A/D fault

Signal overflow

Coil open

Vel. span>10m/s

Vel. span<0.3m/s

P.span>1000p/s

P.span>500p/s

P.span>25p/s

P.span>15p/s

P.span>10p/s

P.span>5p/s

P.span<.0001p/s

T.span>1000p/s

T.span<.0001p/s

Analog lmt error

Empty pipe

Multi range err

Excitation failure

EEPROM no set

EEPROM default

Dev id not
entered

Normal status

Alarm occurrence
(At occurrence of error
No.2 to 25)

Microprocessor failure

EEPROM failure

A/D converter failure

Excessive input signal

Flow tube coil open-circuit

Span velocity setting
exceeds 11m/s.

Span velocity setting is
0.2m/s or less.

Pulse output rate exceeds
1100p/s at 50% duty.
It exceeds 1000p/s at
0.5ms pulse width.

Pulse output rate exceeds
500p/s at 1ms pulse width.

Pulse output rate exceeds
25p/s at 20ms pulse width.

Pulse output rate exceeds
15p/s at 33ms pulse width.

Pulse output rate exceeds
10p/s at 50ms pulse width.

Pulse output rate exceeds
5p/s at 100ms pulse width

Pulse output rate is
0.00005p/s or less.

Totalization rate exceeds
1100p/s.

Totalization rate is
0.00005p/s or less.

Analog low limit setting
exceeds analog high limit
setting.

Pipe is not filled with
fluid or insulating material
attached to electrodes.

“Span” setting exceeds
“Forward span2” setting
at Auto 2 ranges.

Excitation circuit failure

Default values have not
been set in EEPROM.

EEPROM has been
initialized.

Device ID has not been
entered.

Status
group 1

Status
group 2

Status
group 3

Contact the nearest
Yokogawa office or
service center.

Check the followings:
• Mix of the signal, power

supply, excitation and
other cables

• Stray currents in the

measured fluid

• Incorrect grounding

Contact the nearest
Yokogawa office or
service center.

Change settings.

Fill the flow tube with
fluid or clean the flow
tube inside.

Change settings.

Contact the nearest
Yokogawa office or
service center.

Advertising