Yokogawa 202 Field Mounting Rate Totalizer User Manual

Page 18

Advertising
background image

3.3 TOTAL CONVERSION

The Total Conversion feature enables the rate to be displayed in one engineering
unit (eg. gallons/minute) and the totals to be displayed in another engineering
unit (eg. barrels).

The Span is always programmed in the unit relating to

Rate, and the Total

Conversion constant is a division factor which can be used to convert the totals to
the different unit. The Total Conversion factor affects the resettable and
accumulated totals.

For Example.

If the Rate is required in gallons per minute:

1. The Span would be programmed as gallons per minute
2. The timebase would be programmed as minutes

If the Totals are required in barrels:

3. The Total Conversion factor is programmed as 42 (there are 42

gallons in a barrel). All totals will now totalise in barrels.

Some common units are given below together with the Total Conversion constant
which should be programmed.

Rate*

Totals

TOTCON

Gallons (US)/

Barrels (oil)

42.000

Litres/

Kilolitres

1000

ml/

Litres

1000

Mgallons/

Acre-feet

0.32587

* Units per second, minute, hour or day. The timebase is programmed
separately during Programming.

16 Programming

Advertising