Yokogawa 414 Batch Controller User Manual

Page 52

Advertising
background image

50 Installation

7.2 WIRING DESIGNATIONS FOR THE 414D & 414B

Terminal

Model 414D

Model 414B

1

Calibration Link

Calibration Link

2

Signal Ground

Signal Ground

3

Not To Be Used

Not To Be Used

4

Remote Display Switch

Not To Be Used

5

Remote Batch Set Switch

Not To Be Used

6

Not To Be Used

Not To Be Used

7

Flow Alarm

Not To Be Used

8

Flow Common (-)

Flow Common (-)

9

Flow Pulse Input

Flow Pulse Input

10

Pulse Out

Not To Be Used

11

DC Power Out (8-24 VDC)

DC Power Out (8-24 VDC)

12

DC Ground

DC Ground

13

DC Power Input

DC Power Input

14

Not To Be Used

Not To Be Used

Terminal

RS232/422/485 Option

20

RS232 Signal Ground

21

RS232 Data In

22

RS232 Data Out

23

RS422/485 (-) Data Out

24

RS422/485 (+) Data Out

25

RS422/485 (-) Data In

26

RS422/485 (+) Data In

27

RS232 CTS

Terminal

Relay Output & Switches

28

Remote RUN Switch

29

Remote STOP Switch

30

End of Batch/Pump Control Signal

31

Relay 2 - Normally Open

32

Relay 2 - Normally Closed

33

Relay 2 - Common

34

Relay 1 - Normally Open

35

Relay 1 - Normally Closed

36

Relay 1 - Common

Advertising