background image

8

IM 04L41B01-02E

Installation and W

iring

Recommended Replacement

Periods for W

orn Parts

Setup Items and

Default V

alues

Communication (Ethernet) > FTP client > FTP connection

Setup Item

Selectable Range or Selections

Default Value

Setting

FTP connection

Primary/Secondary

Primary

FTP server name

64 characters or less

Port number

0 to 65535

21

Login name

32 characters or less

Password

32 characters or less

******...***

Account

32 characters or less

PASV mode

On/Off

Off

Initial path

64 characters or less

Communication (Ethernet) > SNTP client

Setup Item

Selectable Range or Selections

Default Value

Setting

Use/Not

Use/Not

Not

Server name

64 characters or less

Port number

0 to 65535

123

Access interval

Off/1h/8h/12h/24h

8h

Access reference time

00:00 to 23:59

00:00

Access timeout

10s/30s/90s

30s

Time adjust on Start action

On/Off

Off

Communication (Ethernet) > Modbus client > Basic settings

Setup Item

Selectable Range or Selections

Default Value

Setting

Read cycle

125ms/250ms/500ms/1s/2s/5s/10s

1s

Retry interva

Off/10s/20s/30s/1min/2min/5min/10min/
20min/30min/1h

2min

Communication (Ethernet) > Modbus client > Modbus server settings

Setup Item

Selectable Range or Selections

Default Value

Setting

Server number

1-8/9-16

1-8

Port
Modbus server name
Unit
No.

0 to 65535
64 characters or less
Auto/Fixed
0 to 255

502

Auto
1

Communication (Ethernet) > Modbus client > Command settings

Setup Item

Selectable Range or Selections

Default Value

Setting

Client command number

1-8/9-16

1-8

1 to 16
First
Last
Server
Regi.
Type

Off/R/R-M/W/W-M/E-M

*3

Depends on the command type.
Depends on the command type.
1/2/3/.../15/16
Numerical value
INT16/UINT16/INT32_B/INT32_L/UINT32_B/
UINT32_L/FLOAT_B/FLOAT_L

Off


1
30001
INT16

Communication (Ethernet) > Password management > KDC connection (/AS1 option)

*3

Setup Item

Selectable Range or Selections

Default Value

Setting

KDC connection

Primary/Secondary

Primary

KDC server name

64 characters or less

Port number

0 to 65535

88