Yokogawa Removable Chassis DX1000N User Manual

Page 298

Advertising
background image

12-4

IM 04L41B01-01E

Information display

Alarm summary display Displays a log of up to 1000 alarms.

Specify an alarm with the cursor and jump to the corresponding section on the historical trend

display.

Message summary display

Time and content of up to 450 messages (including 50 add messages)

Specify a message with the cursor and jump to the corresponding section on the historical trend

display.

Memory summary display Displays the information of the data in the memory.

Specify a file with the cursor and jump to the corresponding section on the historical trend display.

Save the data in the internal memory to the external storage medium using keys.

Report (/M1 and /PM1) Displays report data from the internal memory

Stacked bar graph (/M1 and /PM1; Release number 3 or later)

Displays the report data of each report group in a stacked bar graph.

Display formats: H+D (hourly data is used for the display), Day+Week (daily data is used for the

display), D+M (daily data is used for the display)

Report groups:

Report channels are arranged in groups of sixes starting with the first channel

(R001). The group arrangements are fixed.

Scale/grid: Fixed at four divisions

Update interval: 1 s

The report data of the channels in the specified group is displayed in a stacked bar graph.

However, only channels that have the same unit of measurement as the first channel in the group

are displayed.

Status Display

Relay status display:

Displays the ON/OFF status of the alarm output relay and internal switch.

Modbus client status:

Displays the communication status on the Modbus client

Modbus master condition: Displays the communication status on the Modbus master

Event switch display (release number 3 or later): Displays the status of the event level switches.

Log display

Displays the login log (only for the DX without /AS1), error log, communication log, FTP log, Web

log, e-mail log, SNTP log, DHCP log, Modbus log, operation log (/AS1 option; release numbers 4

and later), and change settings log (/AS1 option; release numbers 4 and later)..

Alarm annunciator display (release number 3 or later)

Display windows: 24 max.

Display window label characters: 32 characters × 5 lines max. Comment text blocks are used.

Custom display

Through operations such as size adjustments and attribute configurations, display components

(such as the trend, digital, and bar graph displays) can be arranged to create a custom display. The

display data that is created can be saved to internal memory or to an external medium (CF). The

saved data can be loaded and displayed.

Number of displays: 28 (3 in the internal memory and 25 in a CF card)

System information display Displays the number of measurement and computation channels, options, remote controller ID,

MAC address, firmware version, and internal memory capacity.

Network information display Displays the DX network setup information.

12.2 Display Function

Advertising
This manual is related to the following products: