Installation and Wiring

2.5 Connecting the Extension Cables (only for use

with the expandable type DA100)

Extension Cables

Any of the following extension cables can be used for connections between the DA100 main unit
and subunits or for connections between subunits.

Name

Model

Description

Extension cable

DV200-000

Length: 0.5m

Extension cable

DV200-001

Length: 1m

Extension cable

DV200-002

Length: 2m

Extension cable

DV200-005

Length: 5m

Extension cable

DV200-010

Length: 10m

Extension cable

DV200-020

Length: 20m

Extension cable

DV200-050

Length: 50m

Extension cable

DV200-100

Length: 100m

Extension cable

DV200-200

Length: 200m

Extension cable

DV200-300

Length: 300m

Extension cable

DV200-400

Length: 400m

Extension cable

DV200-500

Length: 500m

Connecting Procedure

Open the lid that covers the connector and insert the plug of the extension cable in the connector
until you hear a click. Since both connectors are identical, it makes no difference which connector
you use. Furthermore, since both plugs of the cable are identical, you may use either end.
When pulling the plug from the connector, gently press the peg of the plug and pull it forward.

Lid

Plug

Extension cable

Points to Note when Using the Extension Cables

· The maximum rated temperature is 60

°C;

· Never disconnect the extension cable from the connector by pulling the cable, since this might

damage the signal cable. Always hold the plug.

· When wiring the extension cable through a cable duct, or metal pipe or such, protect the peg on

top of the plug by covering it with tape.

· Fasten the cables in such a way that no force is being applied to connector or plug.
· To prevent the wire from snapping, etc. do no apply a pulling force of 70N or more. Furthermore,

do not bend the cable in a radius of 3 centimeters or less.

· For wiring conditions, refer to 2.9 Countering Noise.

Note

When several sub-units are connected, and the power is turned off of one of them, the other connected sub-

units which are further away from the main unit will not be recognized anymore.