• Example

Reads in batch the measured values and maximum/minimum value of PR300 with station
number 01.

[Command]

[STX]DGA01

ᮀᮀ

[ETX][CR]

Returns the following response for the above command.

[Response]

[STX]DGA01100001000010000+1.000E+31.000E+31.000E+3G0.8001.000E+31.000E+21.000E+3

ᮀᮀ

[ETX][CR]

(1)

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(1) Active energy: 10000 kWh, (2) Optional electric energy (previous value):
10000 Wh, (3) Optional electric energy (current value): 10000 Wh, (4) Active
power: +1.000E+3 W (1000 W), (5) Voltage-1: 1.000E+3 V (1000 V),
(6) Current-1: 1.000E+3 A (1000 A), (7) Power factor: G0.800,
(8) Maximum voltage-1: 1.000E+3 V (1000 V), (9) Minimum voltage-1:
1.000E+2 V (100 V), (10) Maximum current-1: 1.000E+3 A (1000 A)

Parameter: B (Reads maximum voltage-1), Parameter: C (Reads minimum
voltage-1), Parameter: N (Reads maximum voltage-2), Parameter: P (Reads
maximum voltage-3), Parameter: Q (Reads minimum voltage-2), Parameter: R
(Reads minimum voltage-3)

• Function

Reads the maximum voltage-1 by parameter: B, the minimum voltage-1 by parameter C,
the maximum voltage-2 by parameter: N, the maximum voltage-3 by parameter: P, the
minimum voltage-2 by parameter: Q, and the minimum voltage-3 by parameter: R.

• Command/response

Number

of bytes

1

2

1

2

2

1

1

Command

element

STX

DG

B

(C)
(N)
(P)
(Q)
(R)

Station

number

(ADR)

Checksum ETX

CR

There is no command data for data reading.

1

2

1

2

8

Response

element

STX

DG

B

(C)
(N)
(P)
(Q)
(R)

Station

number

(ADR)

ٗ

.

ٗٗٗ

E

ϩ᭺

2

1

1

Checksum ETX

CR

Number

of bytes

Response data is returned as an 8-byte ASCII character string (0.000E+0 to 9.999E+6).