Waste Coolant

Overflow

Clear Hose

Tank

New Coolant

Tank

Cone Adapter

Adapter Hose

Radiator

Valve

Pump

Water

Block

Engine

Heater

Core

Empty Radiator

1.

Run the vehicle with the heater turned on to bring the engine to operating temperature. Turn
the engine off.

2.

Turn all panel valves to the Home Position as shown on page 4.

3.

Connect shop air to VCX Shop Air Coupler.

4.

Turn all panel valves to the Empty Radiator position as shown in the illustration below. This
orientation can also be obtained by positioning the panel valves toward the black highlights
closest to each valve.

5.

Insert the Adapter Hose into the Cone Adapter. Insert end of Adapter hose into overflow tank.
Turn the Adapter Hose Valve to the open position to withdraw the coolant.

NEW COOLANT

FILL NEW TANK
EMPTY RADIATOR

FILL RADIATOR

FILL NEW TANK

EMPTY NEW TANK
TOP OFF

VCX-1

HOME

EMPTY RADIATOR

EMPTY WASTE TANK

HOME

WASTE COOLANT

EMPTY NEW TANK

TOP OFF

EMPTY WASTE TANK

(PRESSURE)

HOME

(VACUUM)