Vcx- 4, Fill radiator, Page 9 – MAHLE RTI VCX-4 User Manual

Page 10

Advertising
background image

Page 9

Fill Radiator

Fill Radiator
1.

Turn all panel valves to the Home position.

2.

Connect shop air to VCX Shop Air Coupler.

3.

Turn all panel valves to the Fill Radiator position shown in the illustration below, this orientation can
also be obtained by positioning the panel valves toward the magenta highlights closest to each valve.
Verify that the Cone Adapter Valve is open.

4.

Turn the appropriate New Tank Valve to fill from the corresponding tank. Note that New Tank 1 is
used in the illustration shown below.

5.

New coolant is automatically pulled out of the VCX New Coolant Tank and into the vehicle radiator
through the clear hose.

NOTE: IF THE CONE ADAPTER BECOMES DISLODGED BEFORE YOU CAN BEGIN THIS

PROCESS YOU MUST RERUN THE EMPTY RADIATOR FUNCTION, WITHOUT STARTING
THE VEHICLE, TO REGAIN THE VACUUM NEEDED TO FILL THE VEHICLE COOLANT
SYSTEM.

6.

Once the coolant stops moving through the clear hose turn all of the panel valves back to the Home
position and remove the Cone Adapter from the radiator.

7.

Turn all valves to the Home position.

8.

Close the Cone Adapter Valve.

New

Waste

3

New

1

Engine

Block

PINCH
HOSE

Radiator

Clear Hose

Plug Adapter

Overflow

Cone

Hose

Pump

Water

2

New

AFTER EVERY PROCEDURE

TURN ALL VALVES TO HOME

HOME

FILL NEW TANK

EMPTY NEW TANK

EMPTY WASTE TANK

EMPTY WASTE TANK

(PRESSURE)

TOP OFF

EMPTY NEW TANK

EMPTY RADIATOR

(VACUUM)

EMPTY RADIATOR

FILL NEW TANK

TOP OFF

EMPTY NEW TANK

FILL RADIATOR

FILL NEW TANK

HOME

TOP OFF

VACUUM GAUGE

HOME

ON

HOME

HOME

ON

HOME

ON

NEW 2

NEW 1

NEW 3

SELECT NEW COOLANT SOURCE

TURN ONE VALVE ON TO

VCX- 4

Advertising