1

2

3

12

110

E

N

L

80

70

8

8

(Dims. in mm)

Fig. 3

Fig. 5

Fig. 4

Cable Gland & Supply Cord Fitting Instructions (Single phase range)

The cable gland assembly Fig. 5 (items 1 & 2) provides the necessary protection against

ingress of solid objects and moisture as well as providing cable retention.

Assembly instructions are as follows: -

1. Ensure selected cable sheath

diameter is within the permitted range

(6.5 to 9.5 mm).

2. Strip and prepare the cable sheath

and insulators as shown in Fig. 3.

3. Disassemble cable gland as shown in

Fig. 5 and insert cable into position

ensuring ‘O’-ring (item 1) is placed

over the cable before the clamping

insert (item 2) is tightened.

4. Consolidate the stranded conductor

ends by twisting and shape the earth conductor

as shown in Fig. 4 (item 3).

5. Remove earth terminal post clamping

components and assemble as shown in

Fig. 4 ensuring shaped conductor is

orientated as shown and all strands of

the conductor are clamped between

the

washers.

6. Insert and secure live and neutral

conductors ensuring all conductor

strands are clamped.

7. Confirm cable routing is as shown in

Fig. 5 and assemble and secure

terminal box lid.