GEO TANGENT ARRAY RIGGING SYSTEM

Assembling Horizontal GEO Arrays

Horizontal GEO arrays are composed exclusively of GEO S830 loudspeakers.

In this configuration, it is imperative that the cabinets are “tight packed,” that is arrayed at 30° splay angles,
matching the trapezoidal sides of the GEO S830 enclosures. This ensures that the wavefronts are truly
tangent and combine without destructive interference.

Up to three Horizontal GEO S830 arrays can be well hung by using the accessory GEOS-HRPL, attached to
the GEO Array Assembly System with 8mm rings and locking nuts. Always use the “LIFT” point for the rear
attachment. To vary the vertical angle of the array, use different points for the front attachment. For mounting
instruction, please refer to the document shipped with the accessory.

Ground stacking Geo Array

Up to 8 GEO S805 cabinets can be
stacked with the accessory GEOS-
GRND
. GEO S830 should never be
ground stacked together with GEO
S805. The stacking configuration is
taken into account in the NS-1 software.
For mounting instruction, please refer to
the document shipped with the
accessory.

Before assembling for stacked
configuration, remove the front pin from
the angle-setting bar and re-attach it at
point 2. This pivot point is the same
distance from the hole at the other end
of the angle-setting bar as point 1 is from
the end of the oblong slot. This makes it
possible to set all angles up to 5° directly
by attaching the angle-setting bar to the
appropriate hole in the plate. For fixed
angles, insert the pin through the hole at
the tip of the angle-setting bar.

Properly adjust GEOS-GRND front and
rear legs so that GEOS stack assembly
footprint remains inside GEOS-GRND
footprint.