SERVICING and TROUBLE SHOOTING (Continued)

RHAON Network Manager

To activate the RHAON Network Manager open RHAION and select Network Manager from the File pull down menu.

The Network Manager will scan the Ethernet network, list all the CobranNet devices it found on the network and identify them by name,

MAC and IP numbers. It also checks for communication errors (dropped packets). Any errors detected will be counted and listed in the

Error column along with a code number identifying the type of error. Notice that the error count continues to increase as the Network Man-

ager continues to scan the network for errors. In the example shown below the ICL-FR Left array obviously has a problem while two other

devices are showing an occasional glitch.

The Age column shows in milliseconds how long it has been since the device was checked by the Network Manager. It is normal for the

numbers to fluctuate rapidly.

The Startup IP column will show the device’s Startup IP address, if a startup IP was

assigned to it. To assign a startup ID to a single device, double right click on one of the

device’s listing to open the dialog box show to the right. It allows you to assign a specific

IP address (a startup IP) to that device. Startup IP addresses will not be lost in case of

a power disruption to the device. You can also assign Startup IP addresses to all the

devices at one time by clicking on the Command pull down menu and selecting Reset all

IP Addresses as Startup.

The Error Code Reference Guide is accessed from the RHAON Help pull down menu.