Nematron iPC-Fanless Series with N2800 CPU User Manual

Page 11

Advertising
background image

________________________________________________________________________________________
Document No. DOC-IPC-003,
User Manual iPC-Series & nPC300, Rev B Rel. 12-2013

Page 11 of 24




NOTE: (ENCLOSED IPC VERSIONS):

A LISTED VESA STYLE MOUNT SUITABLE WITH A MINIMUM LOAD RATING
OF 40 POUNDS SHALL BE USED IN THE END INSTALLATION

FOR USE IN NONHAZARDOUS LOCATIONS ONLY

TYPE 1 ENCLOSURE

WARNING

– EXPLOSION HAZARD –

DO NOT DISCONNECT THE USB PORTS

UNLESS THE POWER HAS BEEN SWITCHED OFF AND THE AREA IS KNOWN
TO BE NON-HAZARDOUS

WARNING

– EXPLOSION HAZARD –

DO NOT DISCONNECT EQUIPMENT

WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS KNOW TO BE FREE
OF IGNITABLE CONCENTRATIONS.

NOTE (RACK MOUNT VERSIONS):

SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C AND D, CLASS
II DIVISION 2, GROUPS F AND G, CLASS III HAZARDOUS LOCATIONS, OR
NONHAZARDOUS LOCATIONS ONLY

FOR RACK MOUNT INSTALLATION ON A TYPE 1 ENCLOSURE WITH
PROVISIONS FOR CLASS I DIVISION 2 WIRING METHODS

TEMPERATURE CODE: T6 (T4A FOR N2800 OPTION)

WARNING

– EXPLOSION HAZARD – SUBSTITUTION OF ANY COMPONENTS

MAY IMPAIR SUITABILITY FOR CLASS I, DIVISION 2