Mounting options, Sti 6402 – STI 6402WIR User Manual

Page 6

Advertising
background image

- 6 -

Mounting Options

TYPICAL DOUBLE DOOR INSTALLATION

STI 6402

*Note: When mounting reed switch on door and the main unit on wall, wire service loop must be used.

TYPICAL DOUBLE DOOR INSTALLATION

STI-6402

Figure 4

Figure 5

Figure 6

POLYCARBONATE COVER

POLYCARBONATE BASE

120 dB HORN

ALARM DURATION

ALARM TRIP DELAY

EXIT DELAY

VOLUME

VIEW OF THE CIRCUIT BOARD

19039 SCREW

6 x 1 1/4 in.

(2) PROVIDED

19018 ANCHOR
(2) PROVIDED

BOTTOM SURFACE AS SHOWN

WIRES THROUGH NOTCH ON

AND ROUTE REED SWITCH

REMOVE FRONT COVER

VIEW SHOWING MAGNET INSTALLATION

MAGNET

NC COM NO GD

V+

RS1

RS2

KEYSW

TERMINAL BLOCK WIRING CONNECTIONS

FORM

C

DRY

CON

TACTS

RE

MOT

E

POWE

R

INPU

T

9-24

VD

C

R

EE

D

SW

ITCH

TE

R

M

IN

ALS

KE

Y

SW

ITCH

TE

RM

IN

ALS

INTERNAL REED SWITCH

(RS1)

ALARM DURATION

ALARM TRIP DELAY

EXIT DELAY

VOLUME

VIEW OF THE CIRCUIT BOARD

MAXIMUM GAP 3/4 in. (19mm)
3/8 in. (9.5mm) ON METAL DOOR
AND FRAME

SPACERS (USE AS NECESSARY)
NOTE: 2 SPACERS UNDER BOTH
MAGNET AND REED SWITCH
MUST BE USED ON STEEL DOORS

4

3

2

1

NC

COM

NO

GD

V+

RS1

RS2

KEY

SW

SLOTS

FLANGES

TERMINAL STRIP

9 VOLT BATTERY

19011 TAMPERPROOF SCREW
(1) PROVIDED

19016 TAMPER WRENCH
(1) PROVIDED

BASE

19014 MOUNTING SCREW
(4) PROVIDED

REED SWITCH

MOUNTING LOCATIONS

(LABELED 1-4)

COVER

NC

COM

NO

GD

V+

RS1

RS2

KEY

SW

4

3

2

1

NC

COM

NO

GD

V+

RS1

RS2

KEY

SW

SLOTS

FLANGES

TERMINAL STRIP

9 VOLT BATTERY

19011 TAMPERPROOF SCREW
(1) PROVIDED

19016 TAMPER WRENCH
(1) PROVIDED

BASE

19014 MOUNTING SCREW
(4) PROVIDED

REED SWITCH

MOUNTING LOCATIONS

(LABELED 1-4)

COVER

4

3

2

1

ALARM SOUNDS WHEN DOOR IS OPENED

EMERGENCY USE ONLY

ON

OFF

NC

COM

NO

GD

V+

RS1

RS2

KEY

SW

SLOTS

FLANGES

TERMINAL STRIP

9 VOLT BATTERY

19011 TAMPERPROOF SCREW
(1) PROVIDED

19016 TAMPER WRENCH
(1) PROVIDED

BASE

19014 MOUNTING SCREW
(4) PROVIDED

REED SWITCH

MOUNTING LOCATIONS

(LABELED 1-4)

COVER

TO KEY
SWITCH

06402 REED SWITCH
(RS2)

OPTIONAL:

TO REMOTE

HORN

STI-6403

TERMINAL BLOCK

VIEW SHOWING INSTALLATION OF

ADDTIONAL REED SWITCH 06402

3/4 in. (19mm)
MAXIMUM GAP
3/8 in. (9.5mm) ON
METAL DOOR AND FRAME

MAGNET ASSEMBLY
(SEE ABOVE FOR INSTALLATION)

DOOR
SWING

6400 SWING

MAGNET

DOOR STOP

MAGNET MUST BE
INSTALLED OPPOSITE
RAISED RIB ON OUTER COVER

19039 SCREW
6 x 1 1/4 in.
(2) PROVIDED

SPACERS - USE
AS NECESSARY

NOTE: (2) SPACERS MUST BE
USED ON STEEL DOORS

19018 ANCHOR
(2) PROVIDED

MAGNET

6400 UNIT

DOOR
SWING

JAM

DOOR STOP

DOOR

TYPICAL FLUSH MOUNT DOOR JAM

INSTALLATION

TYPICAL RECESSED MOUNT DOOR JAM

INSTALLATION

POLYCARBONATE COVER

POLYCARBONATE BASE

120 dB HORN

ALARM DURATION

ALARM TRIP DELAY

EXIT DELAY

VOLUME

VIEW OF THE CIRCUIT BOARD

19039 SCREW

6 x 1 1/4 in.

(2) PROVIDED

19018 ANCHOR
(2) PROVIDED

BOTTOM SURFACE AS SHOWN

WIRES THROUGH NOTCH ON

AND ROUTE REED SWITCH

REMOVE FRONT COVER

VIEW SHOWING MAGNET INSTALLATION

MAGNET

NC COM NO GD

V+

RS1

RS2

KEYSW

TERMINAL BLOCK WIRING CONNECTIONS

FORM

C

DRY

CON

TACTS

RE

MOT

E

POWE

R

INPU

T

9-24

VD

C

R

EE

D

SW

ITCH

TE

R

M

IN

ALS

KE

Y

SW

ITCH

TE

R

M

IN

ALS

INTERNAL REED SWITCH

(RS1)

ALARM DURATION

ALARM TRIP DELAY

EXIT DELAY

VOLUME

VIEW OF THE CIRCUIT BOARD

MAXIMUM GAP 3/4 in. (19mm)
3/8 in. (9.5mm) ON METAL DOOR
AND FRAME

SPACERS (USE AS NECESSARY)
NOTE: 2 SPACERS UNDER BOTH
MAGNET AND REED SWITCH
MUST BE USED ON STEEL DOORS

4

3

2

1

NC

COM

NO

GD

V+

RS1

RS2

KEY

SW

SLOTS

FLANGES

TERMINAL STRIP

9 VOLT BATTERY

19011 TAMPERPROOF SCREW
(1) PROVIDED

19016 TAMPER WRENCH
(1) PROVIDED

BASE

19014 MOUNTING SCREW
(4) PROVIDED

REED SWITCH

MOUNTING LOCATIONS

(LABELED 1-4)

COVER

NC

COM

NO

GD

V+

RS1

RS2

KEY

SW

4

3

2

1

NC

COM

NO

GD

V+

RS1

RS2

KEY

SW

SLOTS

FLANGES

TERMINAL STRIP

9 VOLT BATTERY

19011 TAMPERPROOF SCREW
(1) PROVIDED

19016 TAMPER WRENCH
(1) PROVIDED

BASE

19014 MOUNTING SCREW
(4) PROVIDED

REED SWITCH

MOUNTING LOCATIONS

(LABELED 1-4)

COVER

4

3

2

1

ALARM SOUNDS WHEN DOOR IS OPENED

EMERGENCY USE ONLY

ON

OFF

NC

COM

NO

GD

V+

RS1

RS2

KEY

SW

SLOTS

FLANGES

TERMINAL STRIP

9 VOLT BATTERY

19011 TAMPERPROOF SCREW
(1) PROVIDED

19016 TAMPER WRENCH
(1) PROVIDED

BASE

19014 MOUNTING SCREW
(4) PROVIDED

REED SWITCH

MOUNTING LOCATIONS

(LABELED 1-4)

COVER

TO KEY
SWITCH

06402 REED SWITCH
(RS2)

OPTIONAL:

TO REMOTE

HORN

STI-6403

TERMINAL BLOCK

VIEW SHOWING INSTALLATION OF

ADDTIONAL REED SWITCH 06402

3/4 in. (19mm)
MAXIMUM GAP
3/8 in. (9.5mm) ON
METAL DOOR AND FRAME

MAGNET ASSEMBLY
(SEE ABOVE FOR INSTALLATION)

DOOR
SWING

6400 SWING

MAGNET

DOOR STOP

MAGNET MUST BE
INSTALLED OPPOSITE
RAISED RIB ON OUTER COVER

19039 SCREW
6 x 1 1/4 in.
(2) PROVIDED

SPACERS - USE
AS NECESSARY

NOTE: (2) SPACERS MUST BE
USED ON STEEL DOORS

19018 ANCHOR
(2) PROVIDED

MAGNET

6400 UNIT

DOOR
SWING

JAM

DOOR STOP

DOOR

TYPICAL FLUSH MOUNT DOOR JAM

INSTALLATION

TYPICAL RECESSED MOUNT DOOR JAM

INSTALLATION

Advertising
This manual is related to the following products: