STI 34709 User Manual

Page 2

Advertising
background image

- 2 -

Programming Instructions

1. Remove cover by releasing snap closure located at the bottom center.
2. Put receiver in program mode (refer to receiver instructions for programming).
3. Remove Mylar tab from battery. Unit should immediately program into receiver, if not

press the tamper switch.

4. Motion sensitivity:

· Normal sensitivity: jumper on BOTH PINS

· High sensitivity: remove jumper

Operation:

· Motion sends wireless transmission after 2 or 3 (select via jumper) pulses.
·

Motion stops (locks out) transmitting wireless sensor alarms for 3 minutes after
sending an alarm transmission.
This is to conserve battery life.

· Tamper, when cover is opened.
· Supervisory, every hour.

Mounting Instructions

1. Release holding tab and remove PCB (see internal view for tab location).
2. Remove screw knockouts for mounting.
3. Replace PCB. Make sure bug / insulation foam is installed.
4. Mount at 7.5ft (ideal height) with provided screws and optional anchors.
5. Replace cover. Unit immediately goes into 3 minute walk test. To reset walk test, remove

cover and reattach.

Walk Test LED

1. LED lights for 3 minutes when motion sensed (only during walk test).
2. Wireless transmissions are sent for each detection; so walk test can be used for receiver

test as well.

3. Motion stops (locks out) sensing for 20 seconds after LED flashes.
4. When complete, replace cover fixing screw.

Operation

1.

Motion stops (locks out) transmitting wireless sensor alarms for 3 minutes after
sending an alarm transmission.
This is to conserve battery life.

2. Walk Test LED does not activate in normal operating mode, only works during walk test.
3. Tamper: when cover is opened.
4. Supervisory: every hour.

Advertising