Programming Instructions

1. Remove cover fixing screw from bottom of case – pull apart.
2. Put receiver in program mode (refer to receiver instructions for programming).
3. Remove Mylar tab from battery. Unit should immediately program into receiver, if not

press the tamper switch.

4. Motion sensitivity:

· Normal sensitivity: jumper on BOTH PINS

· High sensitivity: remove jumper

Mounting Instructions

1. Remove sub-base fixing screw located at the top.
2. Separate sub-base from back by gripping black gasket.
3. Mount case back at 7.5ft (ideal height) with provided screws and optional anchors.
4. Reattach sub-base and cover. Unit immediately goes into 3 minute walk test. To reset

walk test, remove cover and reattach.

Walk Test LED

1. LED lights for 3 minutes when motion sensed (only during walk test).
2. Wireless transmissions are sent for each detection; so walk test can be used for receiver

test as well.

3. Motion stops (locks out) sensing for 20 seconds after LED flashes.
4. When complete, replace cover fixing screw.

Operation

1.

Motion stops (locks out) transmitting wireless sensor alarms for 3 minutes after
sending an alarm transmission.
This is to conserve battery life.

2. Walk Test LED does not activate in normal operating mode, only works during walk test.
3. Tamper: when cover is opened.
4. Supervisory: every hour.