STI LT-1UL User Manual

Sti latching/timer model lt-1ul, Relay mode

Advertising
background image

NOTE:
It is important to read, understand and follow all instructions provided with this product. It is the installer’s responsibility to
comply with NFPA 70, 72 & 101, NEC, mounting specifications according to ADA and other applicable codes. This product
is not to be used in place of panic hardware. To avoid electrical shock, DO NOT attempt to install this product when power
is on. After installation and testing are complete, provide a copy of this manual to all personnel responsible for testing and
maintenance of this product.

*For access control installations, power for the LT-1UL Timer must be supplied by a power source Listed to UL294. When
used for access control, this device shall be used a part of an access controlled egress door system. It is up to the local
AHJ to allow use of this device in place of an automatic sensor. For higher security installations, lower time limits should
be used.

STI LATCHING/TIMER MODEL LT-1UL

RELAY ACTIVE LED RED

POWER LED GREEN

1.28 in.

33mm

1.74 in.

44mm

.632 in.

16mm





+

-

*POWER IN

12 - 24 VAC/VDC, 18 mA

TIMER

CONTROL

FORM “C”

DRY CONTACTS

3A, 30VDC

RESET

INPUT COM

TRIGGER

N.C.

COM

N.O.

1





RELAY MODE

N.O. - Relay N.O. -switches with power to circuit - Fail Safe (default)
N.C. - Relay is in same state as with no power to circuit - Fail Secure (cut jumper)
TO CHANGE TIMER SETTINGS (default = 15 seconds): Cut jumpers with “X”, do not cut jumpers
with “

“.


If the trigger is activated during a timing cycle, the timer is restarted.

NOTE: To ensure jumpers do not reattach or short to other components, cut jumper off completely
flush to PCB.

+

-

x

TIMER START

SWITCH

TIMER OVERRIDE

RESET (OPTIONAL)

*POWER IN

12-24 VAC/VDC

TO MAGNETIC LOCK

(FAIL SAFE MODE)

JUMPERS

15 SEC

RELAY MODE JUMPER

30 SEC 45 SEC LATCH





ILLUMINATING GREEN

ILLUMINATING RED

SHOWN: POWER ON

NORMAL CONDITION

x

x

x